TOOLS AND MATERIAL REQUIRED
1. Two adjustable pipe wrenches
2. Open end adjustable wrench
3. Screwdriver
4. Measuring tape
5. Pipe clamp(s) (to hold pipe during installation).
6. Drive point system only - a slip over drive weight pounder
(to pound in drive point).
7. Galvanized pipe - a non-toxic pipe sealing compound or
type to insure air-tight joints.
8. Plastic pipe - a non-toxic cement or tape to insure air-tight
joints
SHALLOW WELL SYSTEMS
Red Jacket convertible jet
pumps can be adapted to
the following shallow well
systems:
Fig. 1A - horizontally to a
shallow well.
Fig. 1B - horizontally to
drive point.
FIGURE 1
TABLE A — WIRING CHART RECOMMENDED WIRE AND FUSE SIZES
Motor HP
Voltage
115
1
3
½
115
½
230
¾
115
¾
230
1
115
1
230
JET PUMP SYSTEMS
Branch Fuse
0-50'
Rat. Amps
15
14
15
14
15
14
20
12
15
14
20
12
15
14
Motor Voltage Change
The A.O. Smith and Emerson jet pump motors both have a
voltage change switch for ease of changing operating
voltage from low (115 volt) to high (230 volt) operation. The
A.O. Smith switch must be pulled out, moved and pushed in.
The Emerson switch is a toggle that can be changed using a
pen tip or a small screwdriver. The Emerson motor switch is
marked 115 and 230.
It is an industry standard procedure to ship
CAUTION
½ hp motors wired at 115 volts, connecting
them to a 230 volt power supply will damage the motor
windings, and/or the capacitor, and/or the overload protec-
tor. This damage is easily diagnosed and will not be covered
as a warranty failure.
Motors of ¾ hp and larger are factory wired for 230 volts.
Connecting them to a 115 volt power supply without chang-
ing the voltage switch will result in poor performance, noisy
operation and overload tripping due to high heat.
DEEP WELL SYSTEMS
Red Jacket convertible jet
pumps can be adapted to the
following deep well systems:
Fig. 1C - horizontally to a 3"
or 4" double well seal.
Fig. 1D - horizontally to a
vertical 2" well adapter.
Distance in Ft. – Meter to Motor
51'-100'
101'-200'
Wire Size
14
12
14
10
14
14
12
10
14
14
12
8
14
14
201'-300'
301'-400'
10
8
8
8
14
14
8
6
14
12
6
6
12
12
401'-500'
8
8
12
4
10
4
10
3