- INSTALLATION OPTIONS
The Wi-Fi system can be installed on several types of automation (excluding automatic barriers).
SLIDING GATE
UP AND OVER GARAGE DOOR
B
- MOUNTING PROTECTIVE DEVICES
NOVA Wi-Fi PHOTOCELLS
- Attach the NOVA Wi-Fi photocells to the poles or columns about
40÷60 cm from the ground and a maximum of 10 cm from the area of
movement or closing or just after the encumbrance of any strip present,
a maximum of 20 meters from the MASTER Wi-Fi.
- Install the receiver in a shaded area or in a position not exposed to
horizontal sunlight.
- It is advisable in every case to place the photocells at the same height
and in line with each other.
- For the correct positioning of the photocells refer to the user installation
manual or to standard EN12445.
If you remove the power of the MASTER Wi-Fi for a long time, the TOUCH Wi-Fi safety strips and the NOVA Wi-Fi photocells
will exhaust faster than normal the charging of their batteries. Keep the MASTER Wi-Fi always properly fed to ensure a
period of three years for the batteries-life, as stated by RIB.
If for instance, the power to the system is cut off every night, the photocells and the safety strips will regularly and
constantly search for the MASTER Wi-Fi without finding it. Therefore, the life span of the batteries may be reduce to less
than one year.
SWING GATE
SECTIONAL GARAGE DOOR
TOUCH Wi-Fi STRIPS
- Attach the TOUCH Wi-Fi strips in the movement or closing area a
maximum of 20 meters from the MASTER Wi-Fi.
SPARK Wi-Fi BLINKER
- Attach the SPARK Wi-Fi blinker a maximum of 20 meters from the
MASTER Wi-Fi, so that it is visible.
WARNING: