Symptoms
The radio transmitter is not emit-
ting a signal (the LED [A] is not lit)
The manoeuvre does not start and
the "ECSBbus" LED [C] on the
control unit does not flash
No manoeuvre starts and the
flashing light is off
No manoeuvre starts and the
flashing light flashes a few times
The manoeuvre starts but it is imme-
diately followed by a reverse run
LED [A]
Off
1 fast red flash each second
2 fast red flashes + pause for
1 second
A
B
FL100W
Led "A" Led "B"
TABLE 15 (fig. 48)
Probable cause and possible solution
• Check whether the battery is empty, replace if required (chapter 11.5 - Usage guide)
• Make sure that the power supply cable is properly inserted into the electrical network socket
• Check to see if the fuses [B] or [C] are blown; if necessary, identify the reason for the failure and then
replace the fuses with others of equal value
• Make sure that the commands are actually received. If the command is delivered to the OPEN input the
relative "OPEN" LED must light up; otherwise if the radio transmitter is used, the [C] LED flashes slowly twice
• Check that the STOP input is active, that is, the LED "STOP" is lit. If this does not happen, check the device
connected to the STOP input
• The photocells test which is carried out at the start of each manoeuvre has not given a positive result; check
them, referring also to compliance with Table 16
• The selected force could be too low for this type of gate. Check to see whether there are any obstacles; if
necessary increase the force as described in section 10.1.1
TABLE 16 (PH100W)
Status
Indicator with batteries inserted: the device is
not powered or is faulty
Indication resulting from the insertion of the
battery or the pressure of the key; the device is
not paired with any system (factory condition)
Indication resulting from the insertion of the
battery or the pressure of the key; the device
is not part of a network, and the procedure for
its installation has been activated and device
is waiting to be recognised by a control unit;
this procedure is activated when you insert
the battery in the device or by pressing the
keypad; it has a duration of 10 seconds from
battery insertion or from the last press of the
button, after which it deactivates automatically
if no control unit has requested its address
Action
Check that the battery is inserted with the correct polarity; if it is
correct check the battery charge; if the battery voltage measure
is less than 1V the battery is empty; if the battery is charged it is
likely that the photocell is broken.
Normal operation; the photocell is ready to be recognised by
the "CL2W" control unit.
Normal operation; if you want the device in question to be add-
ed to the system, activate the device recognition procedure on
the "CL2W" control unit.
key
tasto
P1
Led
P1
key
tasto
P2
Led
P2
key
tasto
P3
Led
P3
key
tasto
P4
Led
P4