Nice MhouseKit WG2W Instructions Et Avertissements Pour L'installation Et L'utilisation page 28

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

2 fast green flashes + pause
for 1 second
1 fast green flash followed by
1 fast red flash + 1 second
pause
1 flash per second, green on
the transmitter
1 slow flash per second,
green on the receiver
1 slow green flash, on receiver
(**)
1 fast green flash, on receiver
(**)
1 very quick flash, green on
the receiver
Green Led steady on
(*) Note - If the indicator colour is red, one of the following problems may be identified: 1) The maximum number of daily manoeuvres has been
exceeded for a long period. - 2) The battery is old and should be replaced. - 3) The solar cell used as a solar charger is damaged. - 4) The device
does not receive sunlight and consequently cannot charge the battery. If the battery is fully charged the led colour is green; otherwise it is red.
(**) Note - There are 10 flash frequencies which indicate the power of the received IR signal.
LED [A]
Off
1 fast red flash each second
2 fast red flashes + pause for
1 second
2 fast green
flashes + pause for 1 second
1 fast green flash followed by
1 fast red flash + 1 second
pause
1 flash per second, green on
the transmitter
(*) Note - If the indicator colour is red, one of the following problems may be identified: 1) The maximum number of daily manoeuvres has been
exceeded for a long period. - 2) The battery is old and should be replaced. - 3) The solar cell used as a solar charger is damaged. - 4) The device
does not receive sunlight and consequently cannot charge the battery.
If the battery is fully charged the led colour is green; otherwise it is red.
26 – English
Indication following battery insertion when the
automation is stopped; the device is paired
with a system and is communicating correctly
with the control unit
Indication following battery insertion when the
automation is stopped; the device is paired
with a system but the control unit does not
communicate (could be switched off)
The automation is moving or in test
The automation is moving or in test and the
device is receiving an optimum infrared signal
level
The automation is moving or in test and the
device is receiving a good infrared signal level
The automation is moving or in test and the
device is receiving a poor infrared signal level
The automation is moving or in test and the
device is receiving a bad infrared signal level
The RX is receiving no signal
TABLE 17 (FL100W)
Status
Indicator with batteries inserted: the device is
not powered or is faulty
Indication resulting from the insertion of the
battery or the pressure of the key; the device is
not paired with any system (factory condition)
Indication resulting from the insertion of the
battery or the pressure of the key; the device
is not part of a network, and the procedure for
its installation has been activated and device
is waiting to be recognised by a control unit;
this procedure is activated when you insert
the battery in the device or by pressing the
keypad; it has a duration of 10 seconds from
battery insertion or from the last press of the
button, after which it deactivates automatically
if no control unit has requested its address
Indication following battery insertion when the
automation is stopped; the device is paired
with a system and is communicating correctly
with the control unit
Indication following battery insertion when the
automation is stopped; the device is paired
with a system but the control unit does not
communicate (could be switched off)
The automation is moving or in test
Normal operation
Check that the automation is actually stopped, that there is no
testing procedure in progress, and that it is powered and not in
stand-by; if the previous tests are positive check the quality of
the radio signal received from the device
Normal operation; if the indicator colour is red, see note (*)
Normal operation; if the indicator colour is red, see note (*)
Normal operation; if the indicator colour is red, see note (*)
Normal operation but check the TX-RX alignment and that the
glasses are properly cleaned; if the indicator colour is red, see
note (*)
If normal operation is limited, check the TX-RX alignment and
that the glasses are properly cleaned; if the indicator colour is
red, see note (*)
Check for any obstruction between TX and RX. Check that the
LED on TX emits a slow flashing. Check the TX-RX alignment.
If normal operation is limited, check the TX-RX alignment and
that the glasses are properly cleaned; if the indicator colour is
red, see note (*)
Action
Check that the battery is inserted with the correct polarity; if it is
correct check the battery charge; if the battery voltage measure
is less than 1V the battery is empty; if the battery is charged it is
likely that the photocell is broken.
Normal operation; the photocell is ready to be recognised by
the "CL2W" control unit.
Normal operation; if you want the device in question to be add-
ed to the system, activate the device recognition procedure on
the "CL2W" control unit.
Normal operation
Check that the automation is actually stopped, that there is no
testing procedure in progress, and that it is powered and not in
stand-by; if the previous tests are positive check the quality of
the radio signal received from the device
Normal operation; if the indicator colour is red, see note (*)

Publicité

Table des Matières
loading