10.Replace and tighten oil fill cap.
11.Dispose of waste properly.
COOLANT FILTER CHANGE PROCEDURE
1. Stop the machine, electrically isolate and vent all trapped pressure.
2. Loosen filter with the correct tool.
3. Remove the filter from the housing.
4. Place the old filter in a sealed bag and dispose of in a safe way.
5. Clean the mating face of the housing taking care to avoid any
particles entering the machine.
6. Remove the new Ingersoll Rand replacement filter from its
protective package.
7. Apply a small amount of lubricant to the filter seal.
8. Screw the new filter down until the seal makes contact with the
housing, then hand tighten a further half turn.
9. Start the compressor and check for leaks.
AIR FILTER ELEMENT CHANGE PROCEDURE
1. Stop the machine, electrically isolate and vent all trapped pressure.
2. Unscrew the retaining cap and withdraw the old element.
3. Fit the new element.
4. Replace the retaining cap.
SEPARATOR CARTRIDGE CHANGE PROCEDURE
1. Stop the machine, electrically isolate and vent all trapped pressure.
2. Loosen separator cartridge with the correct tool.
3. Remove the cartridge from the housing; place it in a sealed bag and
dispose of it safely.
4. Clean the mating face of the housing.
http://air.ingersollrand.com
MAINTENANCE
5. Remove the new Ingersoll Rand replacement cartridge from its
protective package.
6. Apply a small amount of lubricant to the cartridge seal.
7. Screw the new cartridge down until the seal makes contact with the
housing, then hand tighten a further half turn.
8. Start the compressor and check for leaks.
CAUTION
This unit is not designed or intended to operate when
contaminated with silicone. Lubricants, greases or other items
containing silicone should not be used on this unit.
COOLER CLEANING PROCEDURE
1. Stop the machine, electrically isolate and vent all trapped pressure.
2. Remove the rear cover to obtain access to the cooler.
3. Clean the cooler, blowing debris outward away from unit.
4. Rebuild in reverse order.
SETTING THE PRESSURE TRANSDUCER (PT)
TO CHECK THE MAXIMUM DISCHARGE PRESSURE
(Pressure transducer upper trip point)
Slowly close the isolation valve located adjacent to the compressor.
Observe the rise in pressure and ensure that the pressure transducer
opens at the correct Maximum discharge pressure.
The maximum discharge pressure is shown on the machine data plate.
DO NOT exceed these figures.
The compressor will stop once the system pressure rises to this
pressure.
TO CHECK THE TARGET PRESSURE
Observe the line pressure fall and note the point at which the
pressure transducer closes (and starts the compressor).
TO ADJUST THE TARGET PRESSURE
Remove the airend enclosure panel and locate the POT. Turn the POT
adjuster knob clockwise to increase the set point or anti clockwise to
decrease it.
TO CONVERT UNIT FROM VARIABLE SPEED MODE TO FIXED
SPEED MODE.
Remove the airend enclosure panel and locate the toggle switch. Since
the switch is a 2 position , simply toggle between position to vary the
mode.