MAINTENANCE
ELECTRIC DRAIN VALVE

PRODUCT DESCRIPTION

The Electric Drain Valve removes condensed water and oil from the air
receiver tank. Additional drains may be installed throughout your
compressed air system, including aftercoolers, filters, drip legs and
dryers.
The Electric Drain Valve operates on a timer which can be set to
automatically drain the air receiver tank at operator determined
intervals.
Key features include:
• 100% continuous duty
• NEMA 4 (IP 55) enclosure
• Adjustable time on (0.5
• Adjustable time off (0.5
• Stainless steel operator
• LED to indicate electrical power is on
• LED to indicate valve is open
• Manual override
OPERATION
1. Open the strainer ball valve.
Strainer Ball Valve.
OPEN
2. Set the "time off" and "time on" knobs. See TIMER SETTINGS
(below) for an explanation of the settings.
3. During compressor operation, check for air leaks.
IRN 7.5 - 15 HP (5.5 - 11 kW)
10 seconds)
45 minutes)
CLOSED
TIMER SETTINGS
The "time off" setting determines the interval between cycles from 30
seconds to 45 minutes. The "time on" setting determines the actual time
the compressor drains condensate.
The timer's cycle rate and drain opening time should be adjusted to
open just long enough to discharge the condensate. The timer is
properly set when it opens and discharges condensate and then vents
air for approximately one second before closing. Adjustments may be
made depending on many factors, including humidity and duty cycle.
AIR FILTER MAINTENANCE
In order to ensure optimum compressed air quality the filter element
should be replaced as follows. (Used filter elements must be disposed
of in accordance with local regulations.)
Use only genuine Ingersoll Rand replacement elements.
http://air.ingersollrand.com