How to use the Temperature Controller
Circulation Function (with timer)
Be sure prior to using the timer that the clock time is correct. Unless the clock is set, the timer setting will not be
accessible.
1. Ensure the controller is "ON"
2. Press the "TIMER" button. "TIMER 1" will be displayed. Timer 1 will be preset for 6AM-9AM and 5PM-10PM.
The range that is programmed will be filled in "white". Each "white" section represents 1 hour. When the
time is in the range that is programmed, the circulation function will start automatically showing the
circulation icon. When the programmed range comes to an end, the circulation function will stop
automatically and the circulation icon will no longer be shown.
3. Press the "TIMER" button once more to show "TIMER 2". (The preset is the same as "TIMER 1")
4. Press the "TIMER" button once more to exit from timer setting and the timer setting display will no longer be
shown.
The user can alternate between timers by simply pressing the "TIMER" button once the programming
has already been completed and exited
When using the "TIMER" function, the user may want to consider setting the program to be activated on the grid
icon block before the desired time water is needed to ensure hot water at the desired time
Example:
NOTE
NOTE
If hot water is desired for 6AM, the program can be set for 5AM to ensure that
at 6AM the water is already at the desired temperature.
KBP Series Manual
NOTICE
In the event of a loss of power, the clock
will have to be reset and the timer
feature will need to be turned back on.
Failure to do so will cause the timer
feature not to function.