Prepare For Installation; Materials Needed - Rinnai Rur98I Manuel D'installation Et D'utilisation

Masquer les pouces Voir aussi pour RUR98i:
Table des Matières
Les langues disponibles

Les langues disponibles

General Instructions (continued)
The appliance must be isolated from the gas supply
piping system by closing its individual manual
shutoff valve during any pressure testing of the gas
supply piping system at test pressures equal to or
less than 1/2 psi (3.5 kPa) (13.84 in W.C.).
You must follow the installation instructions and
those in Care and Maintenance for adequate
combustion air intake and exhaust.
INFORMATION
If the water heater is installed in a closed water
supply system, such as one having a backflow
preventer in the cold water supply line, means
shall be provided to control thermal expansion.
Contact the water supplier or local plumbing
inspector on how to control thermal expansion.
Should overheating occur or the gas supply fail to
shut off, turn off the manual gas control valve to
the appliance.
Keep the air intake location free of chemicals, such
as chlorine or bleach, that produce fumes. These
fumes can damage components and reduce the life
of the appliance.
NOTE
The MC-195T temperature controller is
contained within the Styrofoam packing of the
tankless water heater, be sure not to discard it.
This controller is necessary for operation with this
tankless unit.

Prepare for installation

Parts included
Tankless water heater with integrated pump
Color coded cold (blue) and hot (red) isolation valves
Pressure relief valve
MC-195T temperature controller
Self Tapping Screws (Qty - 2)
Thermal Bypass Valve
Tools needed
Pipe wrenches (2)
Adjustable pliers
Screwdrivers (2)
Wire cutters
Tools that might be needed
Hammer drill with
concrete bits
Saw
Threading machine with
heads and oiler

Materials needed

Soap or gas leak detector
solution
Approved venting
Materials that may be needed
Heat tape
Pipe insulation
Electrical wire and
conduit per local code
Concrete wall anchors
Optional pipe cover
Optional temperature
controller
5/8" ID PVC flexible
tubing
2 conductor 22 AWG
KBP Series Manual
Gloves
Safety glasses
Level
Core drill with diamond
head
Torch set
Copper tubing cutter
Steel pipe cutter
Thermal Expansion Tank
Teflon tape
(recommended) or pipe
compound
wire for controller
Single gang electrical box
Wire nuts
Unions and drain valves
Additional Piping (for
dedicated return
applications)
Pressure Regulator
Check Valve
Air Separator
5

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

Rur98eReu-kbp3237ffud-usReu-kbp3237wd-us

Table des Matières