m
Warning – Risk of electric shock!
Components inside the appliance may have
sharp edges. These may damage the
connecting cable. Do not kink or pinch the
connecting cable during installation.
Risk of electric shock!
It must always be possible to disconnect
the appliance from the electricity supply.
The appliance must only be connected to a
protective contact socket that has been
correctly installed.
The mains plug of the mains power cable
must be easily accessible after installation
of the appliance. If this is not possible, an
all-pole isolating switch must be integrated
into the permanent electrical installation
according to the conditions of overvoltage
category III and according to the
installation regulations.
The permanent electrical installation must
only be wired by a professional electrician.
We recommend installing a residual-current
circuit breaker (RCCB) in the appliance's
power supply circuit.
Risk of electric shock!
Incorrect repairs are dangerous. Repairs
may only be carried out and damaged
power cables replaced by one of our
trained after-sales technicians. If the
appliance is defective, unplug the
appliance from the mains or switch off the
circuit breaker in the fuse box. Contact the
after-sales service.
m
Warning – Danger of suffocation!
Packaging material is dangerous to children.
Never allow children to play with packaging
material.

G eneral information

K
T he surfaces of the appliance are easily damaged.
G e n e r a l i n f o r m a t i o n
Avoid damaging them during installation.

Exhaust duct

Note: The appliance manufacturer does not assume any
warranty for complaints attributable to the pipe section.
The appliance achieves its optimum performance by
means of a short, straight exhaust air pipe and as
large a pipe diameter as possible.
As a result of long rough exhaust air pipes, many
pipe bends or pipe diameters that are smaller than
150 mm, the optimum extraction performance is not
achieved and fan noise is increased.
The pipes or hoses for laying the exhaust air line
must consist of non-combustible material.
Risk of damage from returning condensate. Install the
exhaust duct in such a way that it falls away from the
appliance slightly (1° slope).
Round pipes
An inner diameter of 150 mm is recommended.
Flat ducts
The inner cross-section must correspond to the
diameter of the round pipes.
dia. 150 mm ca. 177 cm
Flat ducts should have no sharp bends.
Use sealing strips for different pipe diameters.
2
en
47