ENGLISH
8.5) Language Menu (
Allows you to set the language on the display programmer.
5 languages are available:
- ITALIAN (
)
- FRENCH (
)
- GERMAN (
)
- ENGLISH (
)
- SPANISH (
)
8.6) MENU DEFAULT (
Restores the preset default values on the control unit. After restoring,
a new autoset operation must be carried out.
8.7) DIAGNOSTICS AND MONITORING
The display on the VENERE D panel shows some useful information,
both during normal operation and in the case of malfunctions.
Diagnostics:
In the case of malfunctions, the display shows a message indicating
which device needs to be checked:
STRT
= START
input activation
STOP
= STOP input activation
PHOT = PHOT input activation
FLT
= FAULT input activation for checked photocells
SWO
= input activation OPENING LIMIT SWITCH
SWC
= input activation CLOSING LIMIT SWITCH
PED
= input activation PEDESTRIAN
OPEN = OPEN input activation
CLS
= CLOSE input activation
In the case where an obstacle is found, the VENERE D panel stops
the door and activates a reverse manoeuvre; at the same time the
display shows the "BAR" message.
Monitoring:
During the opening and closing phases, the display shows four digits
separated by a dot, for example
Figures are constantly updated during the manoeuvre and represent
the instant torque reached by motor 1 (
(opening, closing, slow-down) set in the parameter menu (
These values allow the torque setting to be corrected.
If the istant torque value reached during the manoeuvres turns out
to be considerably close to the threshold value set in the parameter
menu, future operation failures are likely to occur due to wearing or
small door deformations.
It is therefore advisable to check the maximum torque reached dur-
ing some of the manoeuvres carried out in the course of installation,
and if necessary set a value about 5-10 percent points higher in
the parameter menu.
8.8) AUTOSET MENU (
• Bring the door to its closing position.
• Initiate an autoset operation by moving to the appropriate VENERE
D panel menu (Fig.B).
• As soon as the OK button is pressed, the following message will
be displayed ".... .... ....", and the control unit initiates an opening
manoeuvre followed by a closing manoeuvre, during which the
minimum torque value needed for door movement will be auto-
matically set.
During this phase, it is important to avoid obscuring the photocells, as
well as using the START and STOP commands and the display.
• By the end of this operation, the control unit will have automatically
set the optimum torque values. Check and, if necessary, modify
them as described in the programming section.
WARNING: Check that the impact force value measured at
the points established by the EN 12445 standard is lower
than that specified in the EN 12453 standard.
WARNING! During the autoset phase, the obstacle detection
function is not optimised; the installer must check the ope-
rator movement and prevent persons and things from coming
near or stopping within the operating range.
20 -
EOS 120 VENERE D Ver.01
INSTALLATION MANUAL
)
)
) and threshold torque
).
)
8.9) LIMIT-SWITCH ADJUSTMENT MENU
The VENERE D control panel is provided with an adjustment menu
for opening and closing limit switches, which simplify the installation
procedure.
Making reference to Fig. 18 and 19, and Fig. B showing control panel
programming, proceed as follows:
• Initiate a limit-switch adjustment operation by moving to the
appropriate VENERE D panel menu (Fig.B).
• When the "CLOSE" message is displayed, bring the door to the
required closing position using the "UP" and "DOWN" control unit
buttons, keeping in mind that the "DOWN" button closes the door
whereas the "UP" button opens the door. As soon as the door is
in the required closing position, press the "OK" button in order to
memorise the closing limit-switch position.
• When the "OPEN" message is displayed, bring the leaf to the
desired opening position using the "UP" and "DOWN" buttons on
the control unit, keeping in mind that the "DOWN" button closes
the leaf whereas the "UP" button opens the leaf. As soon as the
door is in the required opening position, press the "OK" button in
order to memorise the opening limit-switch position.
• Correctly position the "carriage lock" and use the screws to fix it
behind the carriage (fig.18 ref.6 A-B).
NOTA: Ces manoeuvres sont effectuées dans la modalité "a
action maintenue", à vitesse réduite et sans l'intervention des
dispositifs de sécurité.
8.10) STATISTICS
After connecting the UNIVERSAL PALMTOP programmer to the
control unit, enter the CONTROL UNIT / STATISTICS menu and
scroll the screenful showing the statistical parameters:
- Board microprocessor software version.
- Number of cycles carried out. If motors are replaced, count the
number of manoeuvres carried out up to that time.
- Number of cycles carried out from the latest maintenance opera-
tion.
It is automatically set to zero after each self-diagnosis or parameter
writing.
- Date of latest maintenance operation. To be updated manually
from the appropriate menu "Update maintenance date".
- Installation description. 16 characters can be entered for instal-
lation identification.
9) INTEGRATED RECEIVER TECHNICAL SPECI-
FICATION
Receiver output channels:
- output channel 1, if activated, controls a START command.
- output channel 2, if activated, controls the excitation of the 2nd
radio channel relay for 1s.
Transmitter versions which can be used:
all Rolling Code transmitters compatible with
9.1) ANTENNA INSTALLATION
Use an antenna tuned to 433MHz.
For Antenna-Receiver connection, use RG8 coaxial cable.
The presence of metallic masses next to the antenna can interfere
with radio reception. In case of insufficient transmitter range, move
the antenna to a more suitable position.
9.2) RECEIVER CONFIGURATION
Cloning operations can be carried out with the special (UNI-
RADIO) programmer only. The on-board receiver combines char-
acteristics of utmost safety in copying variable code (rolling code)
coding with the convenience of carrying out transmitter "cloning"
operations thanks to an exclusive system.
Cloning a transmitter means creating a transmitter which can be
automatically included within the list of the transmitters memorised
in the receiver, either as an addition or as a replacement of a par-
ticular transmitter.
.