6.5. CONNECTION TO POWER SUPPLY
The connection to the power source must be made
by trained and qualified service technicians. The
power cable is supplied with the cooling/freezing
Prior to making the connection, make sure:
• The supply voltage corresponds to the appliance
voltage of 230 V / 50 Hz / 1 ph. Proper operation of
the appliance requires that the voltage should be
within ± 6% of the rated voltage.
• The electrical system used to power the appliance
must be suitable for rated parameters of the ap-
Connection stages:
• Install the thermomagnetic circuit breaker suita-
ble for rated output power of the appliance to be
installed.

7. HOW TO USE

7.1. PLACING TRAYS AND CONTAINERS IN THE REFRIGERANT'S/FREEZER'S CHAMBER
Never stack food items on top of each other. Divide them evenly on the tray or GN container.
EN
Keep vertical space between trays and/or GN containers
In order to ensure optimum circulation of hot air in the refrigerant's/freezer's chamber, a minimum verti-
cal distance of 40 mm between the trays or GN containers is required.
8
counter. A thermomagnetic circuit breaker (field
supply) must be installed between the socket and
the power cable of the appliance.
pliance to be installed.
• The electronic system connected to the counter
complies with applicable requirements. Electrical
connections and installation of the thermomag-
netic circuit-breaker have been performed by a
qualified person.
• Connect the counter to the output on the thermo-
magnetic circuit breaker.
• Make sure the counter is operational (signalled by
an indicator lamp).