Cool Down
Switch Num-
Coolw Down
Per Cycle (in
minutes)
3 (preset at facto-
OFF
ry)
6
ON
Total Cycle Time = Heat Time + Cool Down Time

Test Setting

When testing coin slide operation or other troubleshooting, set
dipswitch with this shorter cycle:
1. Unplug the machine power cord.
2. Record the machine control dipswitch settings. Then set them
all to the off position. Refer to Figure 1.
3. Plug in the machine and initiate a cycle.
NOTE: With all the control dipswitches off, the total
cycle time will be four minutes long.
4. Once all the testing is complete, unplug the machine and re-
set the dipswitches to their original settings.
5. Plug in the machine.
Slide Extension Assembly - Models Through
Serial No. 1211
1. Remove slide extension parts from parts accessories bag in-
cluded in unit.
2. If installing a Greenwald coin slide, position extension lever
(to be installed on extension bracket) with arm that has one
star facing down. Refer to Figure 30 .
©
Copyright, Alliance Laundry Systems LLC -
DO NOT COPY or TRANSMIT
Cycle Reset
Switch Num-
ber
ber
7
OFF
ON
Table 10
8
1. Greenwald Coin Slide
2. Monarch or ESD Coin Slide
3. Two Stars
4. One Star
3. If installing a Monarch or ESD coin slide, position lever with
arm that has two stars facing down. Refer to Figure 30 .
4. Install extension lever with rounded corner facing away from
extension bracket using bolt, one or two flat washers (shims)
(use number of washers included in kit) and nut. Refer to.
Make sure washers are flat against bracket.
35
1
2
4
TLW2088N_SVG
Figure 30
Installation
3
Part No. D512681ENR9