3. Remove the three silver screws holding the three wires to the
terminal block terminals. Remove green earth/ground screw
holding power cord earth/ground wire to rear bulkhead. Save
all four screws.
4. Loosen the strain relief screw and pull the cord or wires out
through the rear of the dryer.
4
1. Silver L1 Terminal Screw
2. Silver Neutral Terminal Screw
3. Silver L2 Terminal Screw
4. Green Earth/Ground Screw
5. Attach one end of green earth/ground wire (supplied in acces-
sories bag) to rear bulkhead using green earth/ground screw
removed in step 3.
NOTE: Do not use power screwdriver when tighten-
ing ground screw or terminal block screws.
1
1. Earth/Ground Screw
6. Use the three silver screws removed in step 3 to attach the
wires from the new power cord and the other end of the green
©
Copyright, Alliance Laundry Systems LLC -
DO NOT COPY or TRANSMIT
1
2
DRY2017N_SVG
Figure 23
DRY2018N_SVG
Figure 24
earth/ground wire to the terminal block as shown in Figure
25 .
NOTE: Green earth/ground wire must be connected
to center (neutral) terminal of terminal block.
3
1. Earth/Ground to Neutral Wire
2. Neutral Terminal
3. L2 Terminal
4. Center (Neutral) Wire
5. Strain Relief (not supplied with dryer)
6. Green Earth/Ground Screw
7. L1 Terminal
8. Earth/Ground Wire
7. Tighten all screws using a screwdriver and reinstall access
cover removed in step 2.
NOTE: Failure to tighten these screws firmly may re-
sult in wire failure at the terminal block.
8. Secure the strain relief to the power cord, or wires, where they
enter the dryer cabinet.
9. Check the continuity of the ground connection before plug-
ging the cord into an outlet. Use an acceptable indicating de-
vice connected to the center grounding pin of the plug and the
green screw on the back of cabinet.
10. Reinstall access cover and screw.
11. Restore power to dryer.

Gas Dryers

Dryer requires 120 Volt, 60 Hertz electrical supply and comes
equipped with a 3-prong earth/ground plug. Refer to serial plate
for specific electrical requirements.
NOTE: The wiring diagram is located in the control