Installation
Improper connection of the equipment earth/ground
conductor can result in a risk of electric shock.
Check with a qualified electrician or service person if
you are in doubt as to whether the unit is properly
connected to a protective earth/ground.
Do not modify the plug provided with the appliance – if it will
not fit the outlet, have a proper outlet installed by a qualified
electrician.
The electric service must be a separate branch, polarized, three-
wire and earth/ground, 120/240 Volt, or 120/208 Volt (refer to se-
rial plate for specific voltage), 60 Hertz, AC single phase circuit
fused with 30 ampere fuses.
The cord and plug assembly (supplied with dryer) should be
plugged into an approved receptacle that is mounted on the wall
adjacent to the dryer. This receptacle should be accessible to the
user or service person when the dryer is in position, to permit dis-
connecting when necessary.
NOTE: Branch circuit wire size requirements to laundry
room outlet are shown in table below.
Wire Length
Less than 4.5 m [15 ft.]
Longer than 4.5 m [15 ft.]
©
Copyright, Alliance Laundry Systems LLC -
DO NOT COPY or TRANSMIT
WARNING
Wire
Listed No. 10 AWG Copper
wire only
Listed No. 8 AWG Copper
wire only
Table 6
1
W893
1. Typical Four-Wire Receptacle
2. Power Cord (Four-Wire)
3. Strain Relief Nut
4. Strain Relief
5. 0 V.A.C
6. 240 ± 12 V.A.C.
7. 120 ± 12 V.A.C.
Electric Dryers with 3-Wire Plug (Requires
Conversion)
120/240 Volt, 60 Hertz, 3-Wire Installation
120/208 Volt, 60 Hertz, 3-Wire Installation
NOTE: The wiring diagram is located in the control
hood.
To reduce the risk of fire, electric shock, serious in-
jury or death, all wiring and protective earth/ground
connections MUST conform with the latest edition of
the National Electrical Code, ANSI/NFPA 70, or the
Canadian Electrical Code, CSA C22.1, and such local
regulations as might apply. It is the customer's re-
sponsibility to have the wiring and fuses installed by
a qualified electrician to make sure adequate electri-
cal power is available to the unit.
NOTE: Use only a new U.L. listed No. 10 (copper wire
only) three or four conductor power supply cord kit rat-
ed 240 Volts (minimum) 30 Amperes and labeled as
suitable for use in a clothes dryer.