5.4. Wiring the external supply

A terminal block enables to supply the device by an external power supply.
1
FR
EN
3
5V + -
1 2 3 4 5 6
Remove the cable gland screw and the
gland seal
5V + -
1 2 3 4 5 6
V+
GND
Remove screws
NB: it is not necessary to unplug the battery when an external supply is connect-
ed.
PAY ATTENTION: to ensure the IP68 protection the correct seal
must be inserted with the wire, the cable gland screw must be
screwed tight and the sole screws must be tighten with a PZ.1
head and a tightening torque of 0.9 N.m.
2
5V + -
1 2 3 4 5 6
4
5V + -
1 2 3 4 5 6
Insert the wire with the correct seal and con-
nect the supply on the "+" (V+) of the termi-
nal block and the ground to the "-" (GND).
Open the device by
pulling on the sole and
the cable gland
WARNING: do not
pull on the wires