2.4.4 Time counters transmission

The product can send a periodic frame 0x59 (with a period transmission every minutes to 45 days) containing the time spent (in seconds) in a
state different from the current state. This frame contains only the time counters of the Channels configured as input and with a detection of
openings only or closings only.
For this mode the associated parameters are:
• The transmission period of the frame «time counters» (register 328)
• Configuration of the channels (registers 320 to 323)
Example:
Register
S328
S320
S322
S321
S323
In this example the 0x59 frame is sent twice a day and contains the time spent in a closed state on channel 3 and the time spent on opened
state on channel 4. The channel 1 is configured to detect both openings and closings so it is not included in this frame.
IMPORTANT NOTE: When the frame 0x59 is sent, counters are not reset.
Product in standby
NO
Period
reached ?
YES
Send frame 0x59
Value encoding
Decimal
Hexadecimal
Hexadecimal
Hexadecimal
Hexadecimal
Change of
NO
state on a
channel ?
YES
Count the time spent
in this state
Value
Result
720
The frame is sent with a period of 720 x 1 minute = 12 h
0x43
Configuration of the channel 1:
• Count of the opening or closing on the dry contact
• Debounce time* of 100 ms
0x00
Configuration of the channel 2:
• Deactivated
• No debounce time*
0xB1
Configuration of the channel 3:
• Count closings only
• Debounce time* of 20 seconds
0x32
Configuration of the channel 4:
• Count openings only
• Debounce time* of 50 ms