Amann Girrbach Ceramill Motion Mode D'emploi page 31

Masquer les pouces Voir aussi pour Ceramill Motion:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Installing the service unit
2
5
Fig. 3
Service unit
1 Compressed-air inlet
2 Compressed-air hose, 250 mm
3 Water separator
4 Compressed-air connection, milling spindle
5 Extraction-hose connection
▷ Mount the service unit on the rear side of the
machine using the knurled screws.
▷ Connect the 250 mm compressed-air hose to
the right-hand connection (viewed from the
front) of the service unit and to the com-
pressed-air connection [4] of the milling
machine.
▷ Connect the 2000 mm compressed-air hose to
the compressed-air inlet [1] of the service unit
and the other end to the compressed-air supply
of the laboratory.
1
3
4
I N S T A L L A T I O N
Compressor requirements
The compressor for the Ceramill Motion must
meet the following minimum requirements:
_ Inlet flow rate: 100 l/min (3.54 CFM)
_ Compressed-air reservoir: min. 50 l
(13.2 gallons)
_ Output pressure. 8 bar / 116 psi
_ Sound pressure level: max. 60 dB(A)
A suction capacity of 70 l/min (2.47 CFM) at 5 bar
(72.5 psi) is required during operation.
Requirements on air purity for the Jäger spin-
dle
When another service unit than the one supplied is
to be used, the following connection conditions
according to DIN-ISO 8573-1 must be ensured:
_ Solid contaminants: Class 3
(particle size max. 5 m, particle density max.
3
5 mg/m
)
_ Water content: Class 4
(max. pressure dew point +3 °C, water content
3
max. 6000 mg/m
)
_ Total oil content: Class 2
(max. oil content 0.1 mg/m
Extraction requirements
When another extraction system than the
Ceramill Airstream is to be used, it must meet the
following requirements:
_ Suction capacity: 56.6 l/min
_ Suitability for zirconium-oxide dusts
_ HEPA microfilter (97.97 %), filter class H12,
dust category M
3
)
31
E N

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

179200

Table des Matières