GENERAL NOTES

Discoloration of walls and ceiling

Brown discoloration is an annoying problem, which is diffi-
cult to solve. It can be caused by dust burning as a result
of poor ventilation, for example, or by cigarette smoke or
candles.
These problems can be avoided by ensuring that the room
the heater is in is properly ventilated. A good guideline for
ventilation is:
New buildings
: 3.24 m
surface of the room.
Existing buildings
: 25.20 m
Use candles and oil lamps as little as possible, keeping the
wick as short as possible.While they enhance the atmos-
phere, candles and oil lamps also cause the formation of
large quantities of unhealthy soot particles in your home.
Cigarette and cigar smoke contains tar, which upon heating
will precipitate on cold or damp walls. If you have a newly
cemented chimney or have had any other reconstructions
/ renovations done, you are advised to wait at least 6
weeks before lighting your fire, to allow the walls, floor
and ceiling to dry out completely.

Lighting the heater for the first time

During the first use, an unpleasant smell may occur, caused
by the vapour of the varnish.This will vanish after some
hours.
That is why we advise you to use the appliance for the
first time on its highest setting, while at the same time
thoroughly ventilating the room in which the heater is
placed.

Extra protection

This heater meets the normal safety standards regarding
surface temperatures, but physical contact with heated
surfaces should be avoided where possible. An additional
guard is recommended to protect young children and eld-
erly, infirmed or handicapped people.

Disposal

When replacing or otherwise removing the appliance, it
should be disposed of in compliance with current
regulations.
Shut off the connecting tap with coupling before com-
mencing disassembly. Undo the coupling between the con-
necting tap and the appliance.The whole appliance can
now be disassembled and removed.

Guarantee

The warranty for your DRU appliance will be provided by
your supplier. In case of malfunctions, you should always
contact him.You supplier will contact DRU if he feels this
is necessary.The factory warranty for your appliance is
valid for 2 years after date of purchase.
3
/ hour per m
2
floor
3
/ hour for a room.
CONVERSION INTRUCTIONS
The conversion must be carried out by a qualified fitter.
Before commencing the conversion:
1. Unplug the appliance
2. Disconnect the gas supply.
Removing the burner unit
To be able to replace essential components, the entire
burner unit must be taken out of the heater.To do this:
- Open the front and the glass pane.
- Remove the vermiculite tray.
- Disconnect the gas supply.
- Take the burner unit out of the
appliance by pulling it forwards
Note that the two burner-protection wires on the right-
hand side must first be undone.
Now you can start to replace the components:
Replacing the components
1. Pilot-light jet (fig 1)
Unscrew the nut (1) at the end of the pilot-light hose,
pull the hose with ring clamp our of the pilot-light burn-
er and remove the jet. Fit the new jet and tighten the
nut on the pilot-light hose firmly.
2. Main burner jet (fig 2)
Remove the burner tray. Remove the jet (2) with a
panner and fit the new one. Replace the burner tray.
3. Fine adjustment jet (fig 3)
Remove the fine adjustment jet (4) from the gas block.
Fit the new fine adjustment jet and tighten firmly.
4. Throttle ring (fig 2)
The throttle ring ring (3) adjust to 12 mm.
5. Adjusting the burner pressure (fig 3, 4, 5)
Reconnect the gas supply to the heater and open the
new gas pipe.
On the gas control block is point of pressure measure-
ment where the burner pressure can easily be
measured with a manometer. Loosen the screw at the
point of pressure measurement (5) and
connect the manometer.
Remove the cover of the gas
control block by removing the screw (6).To convert the
appliance to propane or natural gas the
burner pressure must be adjusted with the pressure reg-
ulating screw (7) as specified in the table. Replace the
cover.
Ignite the pilot light. Set the thermostat to the highest
setting and adjust the burner pressure as specified in the
table. Check the gas tightness! Turn the burner off again,
remove the manometer and tighten the screw at the
point of pressure measurement.