Glass Window; Positioning The Logs; Connecting To The Gas Supply; Throttle Ring - Dru DIABLO Instructions D'installation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

INSTRUCTIONS FOR INSTALLATION
Figure 2 shows how to calculate the total lengths.

Glass window

For the placing of the logs, the window should be
removed.To do so, proceed as follows:
• Remove the four screws of the safety strip of the window
• Take away the strip and subsequently the glass window.
• Make sure that the standing corner strips do not fall.
To re-assemble the glass window please follow the proce-
dure in reverse order.
When doing this, make sure that the glass window secure-
ly seals the combustion chamber.
Broken or otherwise damaged glass should be replaced
immediately.
For safety reasons a guard should be placed in
front of the fire at all times.

Positioning the logs

• Sprinkle the vermiculite evenly over the burner tray and
the surrounding tray, (the vermiculite tray).The vermiculite
is in a plastic bag with the logs.
• Place the largest log against the back wall.
• Sprinkle a few brown embers, black and yellow chips on
top of the vermiculite to create a glowing effect on the
burner bed.The embers and chips are in little bags with
the log set.
• NB: The black and yellow chips are to be sprinkled in the
vermiculite tray only, not in the burner tray.
• Make sure that no vermiculite gets on or into the pilot
light burner, and that no vermiculite is blocking the over-
flow opening (slit) in the burner tray. (see fig. 6, pos 3).
• Now position the rest of the logs as illustrated in fig. 5.
The logs should not be laid in any other way as this could
cause the formation of soot. Neither should the logs touch
pilot light burner.
fig. 5
12

OPERATING INSTRUCTIONS

Do not use any materials other than those
supplied.The supplied materials are incom-
bustible and have been manufactured specifical-
ly for this appliance.

Connecting to the gas supply

Connect the gas supply to the gas control
valve with 3/8" inner thread.
In the connecting pipe an approved connecting
gas tap with a coupling should be included.This
should be placed outside the casing.
Furthermore please note that:
• Expel all air from the supply pipe before cou-
pling the appliance.
• Do not turn the control tap when connect-
ing the gas supply.
• Avoid any tension on the control tap or
pipes.
• Check that the connection is gastight.
Throttle ring (fig. 6, page 45)
The throttle ring (pos 1) is factory-adjusted to 8 mm.This
will produce attractive flames.
NB:The air inlet may never be closed.
OPERATING INSTRUCTIONS
The control buttons are located behind the flap at the bot-
tom of the heater front.

Lighting

Press button A and turn to the left to the small flame
The flame will ignite at
behind the glass is alight. If that is the case, hold button A
firmly pressed for another 5 seconds.Then release button
A and check that the pilot light is still burning. Now turn
button A to the large flame
valve of the control block. Depending on the setting of the
control button B, high or low flames will be visible.
fig. 7
. Check that the pilot light
, which will open the main
.

Publicité