5.5. Component parts, equipment

1
1.4
Type
Type
:
:
N° de série
Typ
:
:
Serial-No.
Serien-Nr.
:
:
Nominal volume
Capacité nominale
Nenninhalt
Surpression de service admissible
Zulässiger Betriebsüberdruck
Permissible working overpressure
Surpression d`essai
Test overpressure
Température de service mini. / maxi. admissible
Prüfüberdruck
Zulässige Betriebstemperatur min. / max.
Permissible working temperature min. / max.
1.9
1.5
1.10
1.6
1.7
                           
1
Basic steel vessel with built-in, exchangeable
butyl-rubber diaphragm for absorption of the
expansion water under atmospheric separation
conditions.
1.1 Name plate - Vessel:
1.2 Bleeder valve, float vent with
air-intake preventer to dissipate
extracted gases into the atmosphere
1.3 Atmospheric pressure balancing connection
Interior of vessel (space between inner vessel
surface and outer diaphragm surface)
1.5 Flange, vessel connection with internally
fitted degassing equipment, screw
union, connection array
valve outflow line and pump suction line,
each with flat gasket (labelling)
1.6 Adjustable feet.
1.7 Capacity sensor with screw-type round
plug connector to signal wire
1.8
Signal wire level sensor
1.10 Markings for pump and valve connection
1.4 Lifting hook, load suspension for transport
1000 Ltr
1.9 Lockshield valve for condensate drainage
1000 Ltr
2
Connection assembly, pre-installed, including
flat seal
2.1 S elf-draining lockshield valve (vessel) with flat
seal, control unit port
2.2 Flexible pressure/suction hose
2.3 P ipe bend, flat sealing, vessel connector
(DN32: 400 - 1000 liter, DN40: 1200 - 1600 liter.)
12
1.2
1.3
1.1
39307 Genthin
Flamco STAG GmbH
GERMANY
Année de fabrication
:
Herstellungsjahr
Year of manufacture
:
:
:
:
litre
litres
:
:
Liter
:
:
bar
:
:
bar
:
:
:
:
°C
2
2.3
2.2
2.1
1.8
3
Fig. FM.017.V01.15
3
Pump module, control module, including type
plate
3.1 Pump pressure pipe, system supply (marking)
3.2 Pressure sensor
3.3 P ump 1 with manual de-aeration
(hex screw with seal)
3.4 P ump 2 with manual de-aeration
(hex screw with seal)
3.5 P ump 1, wet runner, self-priming
A speed select switch, max. position!
B Vent (slotted-head screw with seal)
3.6 P ump 2, wet runner, self-priming
A speed select switch, max. position!
B Vent (slotted-head screw with seal)
3.7 Valve discharge pipe, system discharge (marking)
3.8 Particle filter
3.9 Non-return valve
3.10 Manual regulated valve 1 (diagram)
3.11 Manual regulated valve 2 (diagram)
3.12 Solenoid valve, overflow valve no. 1
3.13 Solenoid valve, overflow valve no. 2
3.14 T op-up line, incorporating the shut-off valve
(lockshield valve), flexible pressure hose, water
meter, solenoid valve, top-up vale, no. 3, and
check valve (optional)
3.15 Isolating fill and drain valve
3.16 Safety valve (vessel)
3.17 Lockshield valve system connection (optional)
3.18 A utomatic breather with air-intake preventer
(MP,DP60-1 -50)
3.19 Control unit, SPCx-lw including type plate
3.20 Control unit, SPCx-hw including type plate
3.21 Bleed pump