Type Key Pump Control Unit; Type Key Controller Unit - Wilo Sinum MP M-2-50 Notice De Montage Et De Mise En Service

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 43
Alphabetic glossary of abbreviations in terminal plan.
Note: mentioned switch settings are in current-free, un-switched situation.
accessory
(SPC Extension volume, pressure analog, optional)
COM
COM interface; serial port
COM
The common port
data
(Data protocol, optional)
drs
(Diaphragm rupture sensor, optional)
extra low voltage Protective low voltage
fault
Error message, common error message Displayed switch setting is error.
F1/2 MS1/2
(Motor circuit-switch 1/2; Motor circuit-switch combination 1/2, SPCx-hw)
gs
(Gas sensor, optional Gas sensor flexible connection assembly)
high voltage
Voltage as per markings on the automat
mains supply
Power feed
mpl
(Minimum pressure limiter, optional)
M3/3.1 V3/3.1
Motor 3 (top-up, optional) / 3.1 (drainage, optional); valve 3 (top-up) / 3.1
(drainage, optional)
M1 V4 K1/MS1
Motor 2 (pressure increase); valve 5 (not applicable); switch 2 / motor circuit-switch combination 2, SPCx-hw
M2 V5 K2/MS2
Motor 2 (pressure increase); valve 5 (not applicable); switch 2 / motor circuit-switch combination 2, SPCx-hw
niveau
Level, content
ohmic load
Ohmic load, resistance
option
(not applicable)
pressure
Pressure
pwm
(Impulse water meter, optional)
ps
(Pressure switch; level switch min. level, top-up pump, optional)
refill / drain
Top-up / (drain , optional)
sensors
Sensors
tc
(Temperature switch, optional)
V1; 1.1
Valve 1; 1.1; parallel, air release valve (pressure drop)
V2
Valve 2; air release valve (pressure drop)
V2.1
Valve 2.1 (not applicable)
5.3. Type key Pump control unit   
E.g.: DP80 - 1 - 50
Key: AB - C - D
Nom. frequency of the operating voltage (Hz): 50 = 50 Hz; 60 = 60 Hz
Pump manufacturer:
Performance class:
Module version:
5.4. Type key Controller unit    
- lw
E.g.:
SPC 1.2
SPC 1.2
- hw - 1 - 1 - 7 - 1 - 0
Key: SPC x - y - A - B - C - D - E
Hardware version
Output range:
lw = low output
MP; DP / P ≤ 2.2 kW
N
hw = high output
MP / P ≤ 4,0 kW;
N
DP / P ≤ 8,0 kW
N
Installation and operating instructions Wilo-Sinum
1; 2; 3; 4; 5
M; 1; 2; 10; 20; 60; 80; 90; 100; 130
MP = Monopump; DP = Duopump
Phase monitoring/SPC-extension module, Ananlogue signalling: 0 = Not present;
Start type:
1 = Direct start; 2 = Soft start
Nominal current range:
1 = 1.1 - 1.6; 2 = 1.4 - 2.0; 3 = 1.8 - 2.5; 4 = 2.2 - 3.2;
5 = 2.8 - 4.0; 6 = 3.5 - 5.5; 7 = 4.5 - 6.3; 8 = 5.5 - 8.0;
9 = 7.0 - 10.0; 20 = 1.0 - 1.6; 21 = 1.6 - 2.5; 22 = 2.5 - 4.0;
23 = 4.0 - 6.3; 24 = 6.3 - 10.0; 25 = 8.0 - 12.0
1 = 1 motor; 2 = 2 motors
Number of motors:
Voltage: 1 = 400 V ± 10 % / 3 N PE / 50/60 Hz
English
Fig. FM.015.V01.15
1 = Present
Fig. FM.016.V01.15
11