Maintenance
7
Maintenance

7.1 Maintenance and inspection

If the cleaning and safety notices provided are observed, the product
will be maintenance free.
▸ Check product regularly for damage and to ensure that it is securely
assembled.
▸ In the event of damage and/or likely repairs, contact the dealer
immediately.
The product must be checked by an authorized dealer before every
re-use or after 24 months at the latest (see Manufacturer's recommen-
dation for rehab products of the SPECTARIS industrial association).

7.2 Cleaning and disinfection

The product can be cleaned and disinfected using commercially availa-
ble agents.
!
IMPORTANT
In the sensitive area of the bathroom, hygiene is particularly
important.
▸ Keep the product clean at all times and wash it regularly.
▸ Disinfect the product by wiping down all generally accessible surfaces
with disinfectant (after disassembling the product, if possible).
!
IMPORTANT
All cleaning agents and disinfectants used must be effective,
compatible with one another and must protect the materials
they are used to clean. For further information on decon-
tamination in Healthcare Environments, please refer to 'The
National Institute for Clinical Excellence' guidelines on Infec-
tion Control www.nice.org.uk/CG002 and your local infection
control policy.
▸ Clean by hand.
▸ Clean without scouring agent.
Shower and Toilett Commode Ocean / Ocean XL
Cleaning in a domestic environment
!
IMPORTANT Risk of damage
▸ Do not disassemble the brackets for the accessories.
1. Remove any accessories fitted.
2. Pull the footrests out of the guides.
3. Remove the seat plate and the backrest cover.
4. Remove the side parts, see Section 4 „Assembly and installation".
5. Reinsert the clips in the seat frame immediately so that they are not
misplaced.
6. Wash the individual parts using a cloth or brush and commercially
available cleaning agents and disinfectants.
7. Rinse the parts with warm water.
8. Dry the parts with a cloth.
9. Re-assemble the product,
see Section 4 „Assembly and installation".
Cleaning in a hospital environment
CAUTION Risk of burning your skin
Allow the product to cool after cleaning in the autoclave.
1. In addition to cleaning as described above, clean the product at
regular intervals at 85 °C for 3 minutes in the autoclave.
Cleaning the backrest cover (optional)
1. Remove the backrest cover.
2. Wash the cover in a washing machine at max. 60 °C
using a mild detergent.
!
IMPORTANT Risk of damage
▸ Washing at high temperatures can cause shrinkage.
▸ Do not dry covers in the tumble dryer.
13