12. Heating at Low
Thermal Output
The thermal output of your
Granada / Kyoto stove is primarily
affected by the quantity of fuel
used.
Do not attempt to slow down the
combustion by reducing the air
supply.
When heating with wood, this
can result in an incomplete bur-
ning process and pose the risk of
explosive-like combustion of the
accumulated wood gases (defl a-
gration).
60

Heating at Low Thermal Output

Procedure
Position of Control
Elements
Close primary air.
Setl primary air slider
(I) on position zero.
Adjust secondary air.
Set secondary air slider (II)
between position 1 and 2.
Place two thin logs
(weighing c. 0.5 kg in
total and measuring
25 cm in length) lying
in the fi re chamber
Tab. 3

13. Emptying the Ash Drawer

For safety's sake, please make sure that you only dispose of ashes once they are cold. While
the ash collects, the lid is located under the ash drawer.
Unlock the ash drawer. Remove both the ash drawer and the lid located underneath it.
Slide the lid onto the ash drawer so that it is closed; this prevents ashes from fl ying around,
which in turn means your home stays clean. To place the ash drawer back into the stove,
proceed in the reverse order.
Piled up ashes can prevent or even block the primary air supply to the stove.
Ensure that the ventilation path for the primary air between the ash drawer and
the bottom of the ash compartment remains clear.