When using a fl oor plate, the safety distances stipulated by DIN 18891 apply.
20
Fig. 2
Distances to Heat-sensitive and Combustible Materials
20
20
20
80
Fig. 3
56
20
50
3.

Installation

Check to make sure that the load-bearing capacity of the fl oor / installation surface is
suffi cient. If necessary, using a fl oor plate to distribute the load can increase the load-
bearing capacity.
In addition, check whether the room in which the Granada / Kyoto is to be installed is
suffi ciently supplied with fresh air. If the windows and doors are tightly sealed, the necessary
supply of fresh air may not be ensured, which can interfere with the draught capability of
the stove and chimney. If additional combustion air inlet openings are required, they are
not permitted to be closed or obstructed.
Simultaneous operation of the stove and the exhaust hood can cause negative pressure to
build up in the room where the stove is installed, which can lead to problems such as fl ue
gas escaping from the stove.
To ensure that air is not drawn out of the room where the stove is installed, we recommend
locking exhaust hoods that guide the air to the outside by means of a window contact
switch.
4.

The Chimney

The Granada / Kyoto has to be connected to a suitable chimney with a minimum effective
chimney height of 4.50 m. With the design 1 reduction panel it can be connected to a
chimney to which other fi replaces are already connected. The chimney cross section should
correspond to the fl ue pipe cross section. If the effective chimney height is too low and/
or the chimney cross section is too large or too small, the draught capability of your stove
can be impaired.
The Granada / Kyoto stove requires a 12 Pa output pressure (chimney draft). At higher
output pressures, the stove emissions increase, which puts a high load on the stove and can
lead to damage. The Granada / Kyoto stove has a maximum permissible output pressure
of 35 Pa.
To limit the output pressure, a butterfl y valve or output pressure limiter can be used.