Wärmepumpenmanager

3 Quick reference instructions

3.1 Selecting the mode operation

Select the desired operating mode by repeatedly pressing the MODEbutton (text message). The operating mode will change 10
seconds after altering the setting (symbol changes on the display).
cooling
The system operates in cooling operation.
summer
Domestic hot water heating and swimming pool water heating only. Frost protection is ensured.
winter
Programmed raise and lower times are automatically activated.
vacation
The temperature is lowered and the domestic hot water is blocked for an adjustable time period.
party
The programmed lowering of the heating characteristic curves is overridden.
2nd heat generat.
Heat pump is blocked. Heat is generated by the 2nd heat generator.
auto
The system switches into the operating modes heating - summer - cooling depending on the outside
temperature

3.2 Changing the settings

Press and hold the MENU button for several seconds
Select the desired menu item with the arrow buttons (
)
Confirm by pressing the ENTER button (
Select the desired submenu item with the arrow buttons (
and
)

3.3 Settings and operating data

Menu for setting system-specific parameters (see Cap. 8 on pag.
7). Dynamic menus hide non-essential settings.
Time
Sets the time and activates automatic
operating mode switching from summer to
winter.
Mode
Various operating mode settings available
(see Cap. 3.2 on pag. 3)
Heating circuit 1 Settings for heating circuit 1
Heating circuit 2 Settings for heating circuit 2
Heating circuit 3 Settings for heating circuit 3
Cooling
Settings for cooling operation
Domestic
hot
Settings
water
preparation
Swimming pool
Settings for swimming pool heating
Date
Sets the date
(required for leap years only)
Language
Sets the language
for menu navigation
L23
and
)
for
domestic
hot
water
452115.66.36 · FD 9709
Confirm with the ENTER button (
the setting
Change the setting to the desired value with the arrow
buttons (
and
Confirm the new value with the ENTER button (
changes with the ESC button
Heating characteristic curve (see Cap. 6 on pag. 6)
The heating characteristic curve can be adjusted to individual
temperature requirements using the hotter/colder buttons on the
main display. Increase or reduce the temperature with the
buttons. For heating circuit 2/3, make this setting in the menu
"Heating circuit 2/Heating circuit 3".
Domestic hot water heating (see Cap. 7 on pag. 6)
The domestic hot water temperature and a shut-off time for
domestic hot water heating can be set in the menu item "Settings
– Domestic hot water". This can be used to change the time for
domestic hot water preparation, for example at night. An option is
also available for time-controlled reheating of domestic hot water
using a flange heater.
Operating data menu (see Cap. on pag. 9)
Displays the measured sensor values.
History menu (see Cap. 8.4 on pag. 14)
Displays runtimes and stored data (e.g. faults).
Displays (see Cap. 9 on pag. 17)
Display the current operating status of the heat pump
system
Alarm messages: (ESC button flashes)
) until the cursor jumps to
)
English
) or discard
/
EN-3