4
Mechanical installation
Wall mounting
EMC−compliant wiring
Conditions for trouble−free operation:
ƒ Except for the mains cable, use shielded cables only.
ƒ Carefully connect the shielding to PE.
ƒ Separate control and mains cables from motor cable!
ƒ Connect motor and mains PE conductors to separate PE terminals.
Fig. 4−2
X1
A
Fig. 4−1
0
Mains cable L1, N, PE or L1, L2, PE
1
PE connection for mains cable
2
Shield connection, motor cable; fix the shield tightly to the sheet with the cable tie
3
Use shielded motor cable (use low−capacitance motor cables)
4
PE connection of motor cable
5
Shield connection, control cable ( fix the shield tightly to the sheet with the cable tie)
6
Shielded control cable
7
Function module
X1
Terminal strip mains connection
X2
Terminal strip motor connection
PES
HF shield connection by large surface connection to PE
96
B
X2
H
l
C
D
E
F
G
8200mot169
Shield connection:
1. Prepare the cable
2. Insert the cable tie
3. Lay the cable into the
cable tie and tighten it.
The shield must be
tightly connected to
the shield sheet.
EDK82MV371 DE/EN/FR 7.0