7
Commissioning
Important controller codes
Code
No.
Name
C0002
Parameter
*
set
s
managemen
t
uSEr
Restoring
the delivery
status
C0002
Transferring
*
parameter
s
sets with the
keypad
uSEr
(Contin
uation)
118
Possible settings
Lenze Selection
0
0
Ready
Lenze setting ð PAR1
1
Lenze setting ð PAR2
2
Lenze setting ð PAR3
3
Lenze setting ð PAR4
4
Lenze setting ð FPAR1
31
Lenze setting ð PAR1 + FPAR1
61
Lenze setting ð PAR2 + FPAR1
62
Lenze setting ð PAR3 + FPAR1
63
Lenze setting ð PAR4 + FPAR1
64
Keypad ð controller
70
with function module application I/O,
INTERBUS, PROFIBUS−DP, LECOM−B,
DeviceNet, CANopen
10
with all other function modules
l
IMPORTANT
PAR1 ... PAR4:
l
Parameter sets of the
controller
l
PAR1 ... PAR4 also
contain the
parameters for the
function modules
standard I/O,
application I/O, AS
interface, system bus
(CAN)
FPAR1:
l
Module−specific
parameter set of the
fieldbus function
modules INTERBUS,
PROFIBUS−DP,
LECOM−B,
DeviceNet/CANopen
l
FPAR1 is saved in the
function module
Restore the delivery
status in the parameter
set selected
Restore the delivery
status in the fieldbus
function module
Restore the delivery
status in the selected
parameter set of the
controller and in the
fieldbus function module
By means of the keypad
you can transfer the
parameter sets to other
controllers.
During the transmission
the access to the
parameters via other
channels is inhibited!
Overwrite all available
parameter sets
(PAR1 ... PAR4, if required
FPAR1) with the
corresponding data of
the keypad