8
Troubleshooting and fault elimination
Fault messages
1)
Keypad
PC
0
noer
71
ccr
a
61
ce0
a
62
ce1
a
63
ce2
a
64
ce3
a
65
ce4
a
66
ce5
a
132
Fault
Cause
No fault
−
System fault
Strong interference
injections on the control
cables
Earth loops in the wiring
Communication
Faulty transmission of
error on AIF
control commands via AIF
(configurable in
C0126)
Communication
CAN−IN1 object receives
error on CAN−IN1
faulty data, or
with sync control
communication is
interrupted
Communication
CAN−IN2 object receives
error on CAN−IN2
faulty data, or
communication is
interrupted
Communication
CAN−IN1 object receives
error on CAN−IN1
faulty data, or
with event or
communication is
time control
interrupted
BUS−OFF
Controller has received too
many faulty telegrams via
(many
the system bus and has been
communication
disconnected from the bus
errors occurred)
CAN time−out
For remote
parameterisation via the
(configurable in
system bus (C0370):
C0126)
Slave does not respond.
Communication monitoring
time has been exceeded
For operation with
application I/O:
Parameter set change−over
has been parameterised
incorrectly
For operation with module
on FIF:
Internal error
l
Remedy
−
Shield control cables
Insert the communication
module firmly into the diagnosis
terminal
l
Check plug connection bus
module ó FIF
l
Check transmitter
l
Increase monitoring time in
C0357/1, if necessary
l
Check plug connection bus
module ó FIF
l
Check transmitter
l
Increase monitoring time in
C0357/2, if necessary
l
Check plug connection bus
module ó FIF
l
Check transmitter
l
Increase monitoring time in
C0357/3, if necessary
l
Check bus termination
l
Check shield connection of
the cables
l
Check PE connection
l
Check bus load, reduce the
baud rate, if necessary
l
Check wiring of the system
bus
l
Check system bus
configuration
The "parameter set
change−over" signal (C0410/13,
C0410/14) must be connected
to the same source in all
parameter sets
Contact Lenze
EDK82MV371 DE/EN/FR 7.0