grammer, and proceed in the following way.
Connect the universal palmtop programmer to the control unit through the
UNIFLAT and UNIDA accessories (See fig. 17). The QSC-D UL control unit does not
supply the universal palmtop programmer with power, and therefore requires
an appropriate supply unit.
Enter the "CONTROL UNITS" menu, and the "PARAMETERS" submenu, then scroll
the display screenfuls using the up/down arrows to set the numerical values of
the parameters listed below.
For the function logics, refer to the "LOGIC" submenu.
In the case where programming is carried out by means of the incorporated
programmer, refer to Fig. A and B and to the paragraph on "Configuration".
N.B.: The QSC-D UL control unit cannot supply the universal palmtop pro-
grammer with power.

15) CONFIGURATION

The display programmer is used to set all the QSC-D UL control panel functions.
The programmer is provided with three pushbuttons for menu scrolling and
function parameter configuration:
+
menu scrolling/value increment key
-
menu scrolling/value reduction key
OK Enter (confirm) key
The simultaneous pressure of the + and - keys is used to exit the active menu and
move to the preceding menu.
The modifications made are only set if the OK key is subsequently pressed.
When the OK key is pressed for the first time, the programming mode is entered.
The following pieces of information appear on the display at first:
-
Control unit software version.
-
Number of total manoeuvres carried out (the value is expressed in hundreds,
therefore the display constantly shows 0000 during the first hundred mano-
euvres).
-
Number of manoeuvres carried out since the latest maintenance operation
(the value is expressed in hundreds, therefore the display constantly shows
0000 during the first hundred manoeuvres).
-
Number of memorised radio control devices.
When the OK key is pressed during the initial presentation phase, the first menu
can be accessed directly.
Here follows a list of the main menus and the respective submenus available.The
predefined parameter is shown between square brackets [ 0 ].
The writing appearing on the display is indicated between round brackets.
Refer to Figures A and B for the configuration procedure.
15.1) Parameters menu
-
Automatic Closing Time (TCA) [ 10s ]
Set the numerical value of the automatic closing time from 3 to 120 seconds.
-
Opening Motor torque (op. t) [ 80% ]
Set the numerical value of the motor torque between 1% and 99%.
-
Closing Motor torque (cls. t) [ 80% ]
Set the numerical value of the motor torque between 1% and 99%.
-
Slow-down opening motor torque (op. t slow) [ 50% ]
(parameters ⇒ address 8)
Set the numerical value of the motor torque between 1% and 99%.
-
Slow-down closing motor torque (cls. t slow) [ 50% ]
(Advanced parameters ⇒ address 9)
Set the numerical value of the motor torque between 1% and 99%.
-
Fast Opening Time (op. speed. time) [ 15 s. ]
(Advanced parameters ⇒ address 6)
Set the time ato normal opening speed (not slowed down), ranging from 1
second to 2 mins.
Fast Closing Time (cls. speed. time) [ 15 s. ]
-
(Advanced parameters ⇒ address 7)
Set the time to normal closing speed (not slowed down), ranging from 1
second to 2 mins.
Note: The slow-down time, on closing and on opening, is obtained by timing
one manoeuvre, and setting a lower value within this parameter. If, for example,
one manoeuvre lasts 15 seconds, set "normal speed time" to 12s to obtain 3s
of slow-down time.
-
Slow-down speed (slov speed) [ 0 ]
(Advanced parameters ⇒ address 5)
Set the slow-down speed by choosing from one of the following values:
0 – slow down disabled
1 – slow down at 50% of normal speed
2 – slow down at 33% of normal speed
3 – slow down at 25% of normal speed
-
Zone (zone) [ 0 ] (Advanced parameters ⇒ address 1)
Set the zone number between a minimum value of 0 and a maximum value
of 127. See paragraph on "Serial connection".
16 -
DEIMOS BT UL Ver. 08
INSTALLATION MANUAL
www.BFTGateOpeners.com | (800) 878-7829
15.2) MENU LOGIQUES (logic)
-
TCA (TCA) [ OFF ]
ON
Activates automatic closing
OFF
Excludes automatic closing
-
3 Steps (3 step) [ OFF ]
ON
Enables 3-step logic. A Start impulse has the following effects:
door closed:
opens
on opening:
stops and enters TCA (if configured)
door open:
closes
on closing:
stops and reopens
OFF
Enables 4-step logic. A Start impulse has the following effects:
door closed:
opens
on opening:
stops and enters TCA (if configured)
door open:
closes
on closing:
stops and does not enter TCA (stop)
after stopping: opens
-
Impulse lock (ibl open) [ OFF ]
ON
The Start impulse has no effect during the opening phase.
OFF
The Start impulse becomes effective during the opening or closing phase.
-
Photocells on opening (photc. open) [ OFF ]
ON:
In case of obscuring, this excludes photocell operation on opening.
During the closing phase, it immediately reverses the motion.
OFF: In case of obscuring, the photocells are active both on opening and on
closing. When a photocell is obscured on closing, it reverses the motion
only after the photocell is disengaged.
-
Photocell test (test phot) [ OFF ] (Advanced logics ⇒ address 14)
ON
Activates photocell check
OFF
Deactivates photocell check
If this setting is not activated (OFF), it inhibits the photocell checking
function, allowing connection of devices not provided with additional
checking contact.
Safety edge testing (test bar) [ OFF ]
-
ON
Switches safety edge testing on.
OFF
Switches safety edge testing off
If disabled (OFF), it inhibits the safety edge testing function, enabling
connection of devices not equipped with supplementary test contacts.
Fault Phot (test phot) [ ON ]
-
ON
The fault input is associated with the photocell test circuit, up to 4 pairs
of tested photocells and one tested safety edge can be connected.
OFF
The fault input is associated with the safety edge test circuit, up to 4 tested
safety edges and one pair of tested photocells can be connected.
-
Prealarm (preal) [ OFF ]
ON
The blinker comes on about 3s before the motors start.
OFF
The blinker comes on at the same time as the motors start
-
Hold-to-run control (hold-to-run) [ OFF ]
ON
Hold-to-run operation: the manoeuvre continues as long as the control
key is kept pressed.(OPEN-CLOSE)
OFF
Impulse operation, according to the 3 or 4 step logic.
-
Start-Close selection (start - close) [ OFF ]
ON
The input between the two terminals 21-22 acts as close
OFF
The input between the two terminals 21-22 acts as start
-
Fixed code (fixed code) [ OFF ]
(Advanced logics ⇒ address 13)
ON
The receiver is configured for operation in fixed-code mode, see paragraph
on "Radio Transmitter Cloning".
OFF
The receiver is configured for operation in rolling-code mode, see paragraph
on "Radio Transmitter Cloning".
-
Radio transmitter programming (radio prog) [ ON ]
(Advanced logics ⇒ address 15)
ON
This enables transmitter storage via radio (REPLAY, CLONI, W LINK):
1 – First press the hidden key (P1) and then the normal key (T1, T2, T3 or
T4) of a transmitter already memorised in standard mode by means of
the radio menu.
2 – Within 10s press the hidden key (P1) and the normal key (T1, T2, T3 or
T4) of a transmitter to be memorised.
The receiver exits the programming mode after 10s, other new transmitters
can be entered before the end of this time.
This mode does not require access to the control panel.
OFF
Wireless memorizing disabled: wireless learning of any remote control
disabled (including CLONI and REPLAY).
-
Master/Slave (Master) [ OFF ] (Advanced logics - address 12)
ON
The control panel is set as Master in a centralised connection.
OFF
The control panel is set as Slave in a centralised connection.
-
ICE (ICE) [ OFF ] (Proxima -> special dip 1)
ON:
The controller automatically adjusts the Amperostop safety trip treshold
at each start up.
This feature is useful when dealing with installations running at low tem-
peratures.