Malfunction
Generator does not
charge
Heating/ventilation
system fails
Hose couplings on
attachments cannot
be connected
9-3
GB
Possible cause
Plug connection is loose Push in plug connec-
V-belt torn
Generator speed too low Check V-belt tension;
Fuse in the fuse box is
defective
Control valve on engine
is defective
Increased pressure
resulting from influence
of heat on the attach-
ment
Increased pressure in
basic unit
Remedy
tion and secure
Replace V-belt
if necessary, tighten
Replace fuse
Make control valve
move freely
Carefully loosen the
coupling at the hose end
above the quick coup-
ling; oil sprays off; ex-
cess pressure drops;
tighten coupling
NOTE
Make sure that the
collected oil cannot
cause any pollution!
Stop the engine. Re-
move the pressure in
the lines by moving the
hand lever on the pilot
valve (4-8/7) several
times circularly