Mynute Green R.S.I. E
H
M4
4
C
M2
[EN] "L-N" Polarisation is recommended
Blu=Blue / Marrone=Brown / Nero=Black /
Rosso=Red/ Bianco=White / Viola=Violet /
Grigio=Grey / Rosa= Pink / Arancione=Orange/
Giallo-verde=Yellow-green
A = 24V Low voltage room thermostat jumper
B = Gas valve
C = Low temperature thermostat - generic alarm
E = External probe
F = External fuse 3.15A F
G = S.BOLL - Water tank probe
H = T.BOLL/POS - Water tank thermostat/domestic
water time programmer
AKL Control board with digital display integrated
P1
Potentiometer to select off - summer - winter –
reset / temperature heating
P2
Not used
P3
Thermoregulation curve preselection
P4
Not used
JP1 Bridge to enable knobs for calibration only
max heating (MAX_CD_ADJ)
JP2 Bridge to reset the heating timer
JP3 Enable front knobs for calibration in service
(MAX, MIN, MAX_CH, RLA)
JP4 Not used
JP5 Heating only operation with provision for exter-
nal storage tank with thermostat (JP8 inserted)
or probe (JP8 not inserted)
JP6 Enable night-time compensation function and
continuous pump
JP7 Enable management of low temperature/stan-
dard installations
JP8 Management of external storage tank with ther-
mostat enabled (jumper inserted)/Management
of external storage tank with probe enabled
(jumper not inserted)
G
B
OPE
OPE
-t°
P.A.
1
2
2
3
1
2
3
1
rosa
CN9
7
1
3V
V Lv
V Hv
1
2
CN3
2
1
1
3
1
CN10
S.M.
S.R.
T.L.A.
-t°
-t°
S.F.
-t°
12
1
CN11
CN1-CN15 Connectors (CN7 local valve kit)
S.W. Chimney sweep function, interruption of purge
cycle and calibration when enabled
E.R. Flame detection electrode
S.C. Condensate sensor
F1
Fuse 3.15A T
M2
Terminal board for external connections: low
temperature thermostat/generic alarm
M3
Terminal board for external connections:
230 V
M4
Terminal board for external connections: water
tank probe/ water tank thermostat or POS
M6
Terminal board for external connections:
Open therm/water tank probe/room thermo-
stat (24 Vdc)
P
Pump
PWM PWM signal
OPE Gas valve operator
V Hv Fan power supply 230 V
V Lv Fan control signal
3V
3-way valve servomotor
E.A Ignition electrode
TSC2 Ignition transformer
P.A. Water pressure switch
T.L.A. Water limit thermostat
S.F. Flue gas probe
S.M. Delivery temperature sensor on primary cir-
cuit
S.R. Return temperature sensor on primary cir-
cuit
[FR] La polarisation "L-N" est recommandée
Blu=Bleu / Marrone=Marron / Nero=Noir /
Rosso=Rouge / Bianco=Blanc / Viola=Violet /
Grigio=Gris / Rosa= Rose / Arancione=Orange/
Giallo-verde=Jaune-vert
F
230 V
L
N
PWM
blu (-)
P
F
marrone (+)
CN12
3
4
4
5
6
CN2
1
CN7
3
CN8
1
CN4
7
TSC2
N
F
E.A.
1 2
3
CN1
Mynute Green C.S.I. E - R.S.I. E
M3
OT+
E
A
-t°
M6
1
CN6
JP6
JP5
JP4
JP3
JP2
JP1
JP7
CN5
JP8
P4
SW1
CN13
P1
P2
CN14
P3
AKL
3
CN4
CN9
1
2
CN3
1
1
3.15A T
F1
CN10
6
4
CN2
1
CN11
1
CN1
12
FA2
FA1
S.C.
E.R.
A = 24V Cavalier de thermostat ambiant basse
tension
B = Vanne de gaz
C = Thermostat basse température - alarme
générique
E = Sonde externe
F = Fusible extérieur 3.15A F
G = S.BOLL - Sonde de réservoir d'eau
H = T.BOLL/POS - Thermostat de réservoir d'eau/
programmateur temporel d'eau sanitaire
AKL Panneau de commande avec écran digital
intégré
P1
Potentiomètre pour sélectionner arrêt - été -
hiver - réinitialisation / chauffage en tempéra-
ture
P2
Non utilisé
P3
Présélection de la courbe de thermorégulation
P4
Non utilisé
JP1 Pont pour permettre de calibrer les boutons
uniquement en chauffage maximum (MAX_
CD_ADJ)
JP2 Pont pour réinitialiser le temporisateur de
chauffage
JP3 Activation des poignées avant de réglage en
service (MAX, MIN, MAX_CH, RLA)
JP4 Non utilisé
JP5 Fonctionnement
prédisposition pour réservoir d'accumulation
extérieur avec thermostat (JP8 inséré) ou ré-
servoir d'accumulation extérieur avec sonde
activée (JP8 non inséré)
JP6 Activation de la fonction de compensation de
nuit et pompe continue
JP7 Gestion de l'activation des installations basse
température/standard
CN12
1
chauffage
seul
avec
193

Publicité

Table des Matières
loading

Table des Matières