Beretta Mynute Green E 12 R.S.I. Manuel D'installation Et D'utilisation page 190

Table des Matières

Publicité

Mynute Green C.S.I. E - R.S.I. E
Mynute Green C.S.I. E
F.L.
4
C
M2
[EN] "L-N" Polarisation is recommended
Blu=Blue / Marrone=Brown / Nero=Black /
Rosso=Red/ Bianco=White / Viola=Violet /
Grigio=Grey / Rosa= Pink / Arancione=Orange/
Giallo-verde=Yellow-green
A = 24V Low voltage room thermostat jumper
B = Gas valve
C = Low temperature thermostat - generic alarm
E = External probe
F = External fuse 3.15A F
AKL Control board with digital display integrated
P1
Potentiometer to select off - summer - winter –
reset / temperature heating
P2
Potentiometer to select DHW set point, ena-
ble/disable preheating function
P3
Thermoregulation curve preselection
P4
Not used
JP1 Bridge to enable knobs for calibration only
max heating (MAX_CD_ADJ)
JP2 Bridge to reset the heating timer
JP3 Enable front knobs for calibration in service
(MAX, MIN, MAX_CH, RLA)
JP4 Absolute domestic hot water thermostat selec-
tor
JP5 Not used
JP6 Enable night-time compensation function and
continuous pump
JP7 Enable management of low temperature/stan-
dard installations
JP8 Jumper inserted - Flow switch
CN1-CN15 Connectors (CN7 local valve kit)
S.W. Chimney sweep function, interruption of purge
cycle and calibration when enabled
E.R. Flame detection electrode
S.C. Condensate sensor
190
B
S.S.
OPE
OPE
P.A.
2
3
1
2
3
1
1
2
3
4
rosa
6
CN9
7
1
V Lv
V Hv
CN3
2
1
1
CN10
3
S.M.
S.R.
T.L.A.
-t°
-t°
S.F.
-t°
12
CN11
1
F1
Fuse 3.15A T
M2
Terminal board for external connections: low
temperature thermostat/generic alarm
M3
Terminal board for external connections:
230 V
M6
Terminal board for external connections:
Open therm/water tank probe/room thermo-
stat (24 Vdc)
P
Pump
PWM PWM signal
OPE Gas valve operator
V Hv Fan power supply 230 V
V Lv Fan control signal
3V
3-way valve servomotor
E.A Ignition electrode
TSC2 Ignition transformer
F.L. Domestic hot water flow switch
S.S. Domestic hot water circuit probe (NTC)
P.A. Water pressure switch
T.L.A. Water limit thermostat
S.F. Flue gas probe
S.M. Delivery temperature sensor on primary cir-
cuit
S.R. Return temperature sensor on primary cir-
cuit
[FR] La polarisation "L-N" est recommandée
Blu=Bleu / Marrone=Marron / Nero=Noir / Rosso=Rouge /
Bianco=Blanc / Viola=Violet / Grigio=Gris / Rosa=
Rose / Arancione=Orange/ Giallo-verde=Jaune-vert
A = 24V Cavalier de thermostat ambiant basse
tension
B = Vanne de gaz
C = Thermostat basse température - alarme
générique
F
230 V
L
N
M3
PWM
blu (-)
P
F
marrone (+)
CN12
4
5
CN2
1
CN7
3V
CN8
1
2
3
1
CN9
7
CN4
1
1
4
1
TSC2
12
N
F
E.A.
1 2
3
CN1
OT+
E
A
-t°
M6
CN12
1
CN6
JP7
JP6
JP5
JP4
JP3
JP2
JP1
CN5
JP8
P4
SW1
CN13
P1
P2
CN14
P3
AKL
3
CN4
1
2
CN3
1
3.15A T
F1
CN10
6
CN2
CN11
1
CN1
1
FA2
FA1
S.C.
E.R.
E = Sonde externe
F = Fusible extérieur 3.15A F
AKL Panneau de commande avec écran digital
intégré
P1
Potentiomètre pour sélectionner arrêt - été - hiver -
réinitialisation / chauffage en température
P2
Potentiomètre de réglage de la température
de l'eau chaude sanitaire, activation/désacti-
vation fonction préchauffage
P3
Présélection de la courbe de thermorégulation
P4
Non utilisé
JP1 Pont pour permettre de calibrer les boutons
uniquement en chauffage maximum (MAX_
CD_ADJ)
JP2 Pont pour réinitialiser le temporisateur de
chauffage
JP3 Activation des poignées avant de réglage en
service (MAX, MIN, MAX_CH, RLA)
JP4 Sélecteur de thermostat d'eau chaude sani-
taire absolue
JP5 Non utilisé
JP6 Activation de la fonction de compensation de
nuit et pompe continue
JP7 Gestion de l'activation des installations basse
température/standard
JP8 Cavalier inséré - Flussostat
CN1-CN15 Connecteurs (kit de vanne locale CN7)
S.W. Fonction nettoyage cheminée, interruption du
cycle de purge et calibrage en cas d'activation
E.R. Électrode de détection de flamme
S.C. Capteur de condensats
F1
Fusible 3.15A T
M2
Bornier pour branchements extérieurs: ther-
mostat basse température/alarme générique

Publicité

Table des Matières
loading

Table des Matières