Specifications). This means that the user can cut for 4 minutes and then
rest the plasma cutter for 6 minutes before using it again.

THERMAL PROTECTION

Constantly exceeding the duty cycle can damage the cutting unit. An
internal thermal protector will open when the duty cycle is exceeded,
shutting OFF all cutting unit functions except the cooling fan. Leave the
cutting unit turned ON with the fan running. The thermal protector will
automatically reset and the cutting unit will function normally again once
it has cooled.
Wait at least another 10 minutes after the thermal protector opens
before resuming cutting. Starting before this additional time may result
in a shortened duty cycle

PREPARATION

WARNING! The plasma cutting unit is 'live' once turned on and
can cause serious electrical and burn injuries if mishandled. Take
all precautions listed in this manual when handling the plasma
cutting unit.
1. Check that all personal protective gear is in place and properly
fitted. (See Safety – Personal Safety).
2. Check that work area preparations are in place (See Safety – Work
Area).
3. Check that all cables and hoses are connected in the correct manner.
4. Check that the plasma cutter unit is working.
4.1 Plug the plasma cutting unit power cord into an outlet that
meets the specified power requirements (see Specifications).
4.2 Press the power switch to turn the plasma cutter unit ON. The
fan should start up and the power indicator will light up.
5. Set the air pressure switch to allow air flow through the torch with
the gas check function. Confirm the air flow is constant and does
not sputter.
ATTACH THE GROUND CLAMP
1.
Clean off dirt, oil, rust, scale, oxidation and paint from the
workpiece where the ground clamp will be attached.