circuit failure will also trigger the LED. The plasma cutter will shut
down.
B
Power Indicator – Illuminates when the power is on
C
Current Control Dial
D
Euro Connector Port – The port is electrically negative (-)
E
Torch Error Indicator - Lights when issue with torch system or air
supply detected and cutting output is disabled as a result. Flashing
light means that torch shield cap is not installed. Continuous light
means likely damaged or missing torch consumables or insufficient
air pressure supply to the torch.
F
Cutting Power Indicator – The LED will glow when the cutting
circuit is active.
G
Test Air Indicator – When set, the compressed air control valve is
open to test the airflow and set the air pressure. The machine
cannot cut when this function is on.
H
Normal Cutting Indicator
I
Perforated Cutting Indicator – The LED glows when grid cutting is
selected.
J
Cutting Mode Selector Button
K
Ground Connector – Connect the ground cable to the port and
connect the ground clamp to the workpiece. The port is electrically
positive (+).
L
Air Pressure Regulator - This air pressure regulator enables you to
adjust line pressure to the tool you are using. Pull the knob
upwards to unlock the knob. Turn the knob clockwise to increase
pressure and counterclockwise to decrease pressure. Push down
to lock it in place.
M
Air Pressure Gauge.
N
Air Inlet – Connection for air hose from a compressor.
O & P
The moisture separator (O) is self-draining, the water-drain
tube exits out the bottom of the clear condensate bowl (P). It
is normal to see moisture coming from this tube periodically. If
excessive amounts of water or oil are being produced in the
16