9.1 Maintenance and cleaning intervals

The specified intervals are standard values and refer to single-shift operation. We recommend recording the
inspections. The date of the inspection, the detected defects and the name of the inspector must be observed.
Daily
Weekly
Monthly

9.2 Replacing the pre-filter

The filter pad (B) is the most important element. When replaced regularly, the service life of the pre-filter
is prolonged. Cleaning the filter pad with compressed air or a hammer is not permitted. The filter pad must
be replaced.
► Check the pre-filter and primary filter and replace as needed.
 9.2 Replacing the pre-filter on page EN-18
 9.3 Replacing the primary filter on page EN-19
► Check the extraction arm and replace as needed.
 9.5 Replacing the extraction arm on page EN-20
► Clean outer surfaces.
 9.4 Cleaning outer surfaces on page EN-19
Turn the On/Off switch (D) to <O>.
1
 Fig. 2 Assembly and use on page EN-10
Pull out the mains plug.
2
Unlock and open the service door using a square
3
wrench.
Remove the pre-filter.
4
A
Remove the spring clamp (A) and filter pad (B).
5
Dispose of the filter pad (B) in accordance with
6
local regulations.
B
 12 Disposal on page EN-22
Insert a new filter pad (B) into the filter grill (C).
7
Insert the spring clamp (A).
8
C
Insert the pre-filter.
9
Close the service door and lock it using
10
a square wrench.

9 Maintenance and cleaning

EN - 17