Decommissioning; Maintenance And Cleaning - Abicor Binzel xFUME ADVANCED Mode D'emploi

Masquer les pouces Voir aussi pour xFUME ADVANCED:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

®
xFUME
ADVANCED

8 Decommissioning

9 Maintenance and cleaning

Scheduled maintenance and cleaning are prerequisites for a long service life and trouble-free operation.
We recommend you clean the device in two steps. The first part involves emptying the dust from the
collecting drawer. Regularly removing dust can lengthen the service life of the filter cartridges. The second
part involves the electrical and mechanical maintenance of the filter system. The maintenance cycle is
determined by the work environment and by the length of the scheduled intervals between maintenance of
the devices. The maintenance cycle is usually three months. If the device is operated for more than 8 hours
a day, the maintenance intervals should be changed as needed.
W
Health risk caused by inhaling harmful dust
The device contains harmful dust that can collect on surfaces and penetrate the ambient air as of the first
use. It can damage the respiratory tract when inhaled.
► Check and wear your personal protective equipment.
► Use the device only in rooms with sufficient ventilation.
► Ensure that all seals on the device are free from dirt and debris.
► The provided filtration system must be used when operating the device.
► The dust collecting drawer must be closed when operating the device.
► Do not open the dust collecting drawer until at least one minute has passed since the device was
► Keep the device closed during operation and during the cleaning process.
► Immediately remove dust deposits from the environment with a dust class H industrial vacuum cleaner
W
Electric shock due to defective cables
Damaged or improperly installed cables can lead to fatal electric shock.
► Check all live cables and connections for proper installation and damage.
► Damaged, deformed or worn parts should only be replaced by a qualified electrician.
W
Risk of crushing
Limbs can be crushed if device components are improperly installed or uninstalled.
► Keep your hands out of the danger zone.
► Check and wear your personal protective equipment.
W
Risk of injury due to unexpected start
If power is supplied during maintenance, cleaning or disassembly, rotating parts can start running
unexpectedly and lead to injuries from cuts.
► Switch off the device.
► Disconnect all electrical connections.
From June 2021
WARNING
switched off.
or a damp cloth.
WARNING
WARNING
CAUTION
8 Decommissioning
Switch the device to Off with the On/Off switch
1
on the control panel.
Disconnect the device from the power supply.
2
EN - 15

Publicité

Table des Matières
loading

Table des Matières