7 Operation

6.3 Controlling the volume flow

A lever on the extraction hood can be used to manually control the volume flow. When the lever is vertical,
the valve is open and the extracted welding fumes flow unimpeded. If the lever is horizontal, the valve closes
and limits the volume flow of the extracted welding fumes.
Fig. 4
A Valve
7 Operation
Health risk caused by inhaling harmful dust
The device contains harmful dust that can collect on surfaces and penetrate the ambient air as of the first
use. It can damage the respiratory tract when inhaled.
► Check and wear your personal protective equipment.
► Use the device only in rooms with sufficient ventilation.
► The provided filtration system must be used when operating the device.
► Do not open the service door until at least one minute has passed since the device was switched off.
► Keep the device closed during operation and during the cleaning process.
► Immediately remove dust deposits from the environment with a dust class H industrial vacuum cleaner
Risk of injury due to fire
Improper use or connection can result in fire. This may result in serious burns.
► Ensure that the operating voltage specified on the nameplate is suitable for the connection voltage.
► Do not use the device to extract welding fumes that result from welding oil-wetted parts.
► Do not use the device to extract flammable substances and liquids.
► Do not use the device in areas subject to dust or gas explosion hazards.
Risk of injury due to moving extraction arm
If the extraction arm is protruding when the device is moved, it could cause injury to people standing
nearby.
► The device should be moved only when the extraction arm is upright.
NOTICE
Material damage due to device tipping over
If the extraction arm is protruding when the device is moved, it could cause the device to tip over.
► The device should be moved only when the extraction arm is upright.
NOTICE
Material damage due to excessive rotation
The extraction arm may become damaged if it is rotated past its limit stop.
► Do not rotate the extraction arm past the limit stop (max. 350°).
EN - 14
Controlling the volume flow
A
B
WARNING
or a damp cloth.
WARNING
CAUTION
B Lever
A
B
xFUME FLEX