Tool Assembly - Milwaukee 4004 Manuel De L'utilisateur

Masquer les pouces Voir aussi pour 4004:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

To reduce the risk of injury, always unplug tool before
attaching or removing accessories or making adjust-
ments. Use only specifi cally recommended accesso-
ries. Others may be hazardous.
Assembling Dymorigs & Vac-U-Rig® Stands
For Cat. No. 4125 & 4130 only (Fig. 1).
Fig. 1
Hex bolt
Socket set
screws (2)
1.
Set the base on the ground. Loosen the hex bolt and nut (wrench not
supplied). Raise the column upright.
2.
To core vertically or horizontally, insert the large column bolt (provided
in separate accessory bag) through the bottom of column and into the
base. Tighten hex bolt and nut (wrench not supplied).
To angle core, tilt the column to the desired angle and tighten the
hex bolt and nut. Save the column bolt for future use when vertical or
horizontal coring.
3.
Tighten the two (2) black socket set screws located on the base with
the supplied wrench.
4.
Screw the four (4) handle spokes (provided in separate accessory bag)
into the hub on the cradle assembly.
For Cat. No. 4115 & 4120 only (Fig. 2).
Fig. 2
Base
1.
Set the base on the ground.
2.
Remove two (2) bolts and two (2) lockwashers from accessory bag.
3.
Place the column in the slot of the base.
4.
Insert two (2) bolts and two (2) lockwashers and tighten securely.
WARNING!
Handle
spoke
Cradle
assembly
Column
Base
Leveling
screws (4)
Column bolts
Cradle as-
sembly
Handle
spoke
Column
Leveling
screws (4)
Column
bolts (2)
Lock washers

TOOL ASSEMBLY

Moving the Handle to the Other Side
For Cat. Nos. 4125 & 4130 only (Fig. 3).
Fig. 3
Socket
screws (4)
1.
Tighten the cradle lock.
2.
Loosen the socket head screw and remove the meter box.
3.
Remove four (4) socket head screws holding the spoked handle hous-
ing.
4.
Turn the assembly around 180°.
5.
Replace the four (4) socket head screws and tighten securely.
6.
Attach meter box to opposite side (see "Mounting the Meter Box").
For Cat. Nos. 4115 & 4120 only (Fig. 4).
Fig. 4
1.
Loosen the cradle lock.
2.
Raise the cradle to the maximum height.
3.
Lift the cradle an additional 1/2" by hand.
4.
Tighten the cradle lock.
5.
Loosen the socket head screw and remove the meter box.
6.
Remove the meter box stud from the cradle.
7.
Remove the screw and washer from the end of the pinion shaft.
8.
Remove the handle and pinion shaft assembly.
9.
Turn the assembly around 180° and insert into cradle.
10. Replace the screw and washer and tighten securely.
11. Replace the meter stud on the side opposite the handle.
12. Attach meter box to opposite side (see "Mounting the Meter Box").
13. Loosen the cradle lock and lower the cradle until the pinion engages
the rack.
14. Tighten the cradle lock.
Bubble
level
Socket
screw
Cradle
Cradle
lock
Socket screw
and washer
Socket
screw
Cradle
Ammeter
gauge
Meter
box
Ammeter
gauge
Meter
box
page 5