FEATURES
PRODUCT SPECIFICATIONS
ENGINE
Engine Type ....................................................... Honda GX390
Fuel Volume ..................................................................... 8 gal.
GENERATOR
Rated Voltage ......................................................... 120V/240V
Rated Amps ...................................................... 58.3 A / 29.2 A
Rated Output ...............................................................7,000 W
KNOW YOUR GENERATOR
See Figure 3.
The safe use of this product requires an understanding of the
information on the product and in this operator's manual as well
as a knowledge of the project you are attempting. Before use
of this product, familiarize yourself with all operating features
and safety rules.
AC CIRCUIT BREAKER
The circuit breaker is provided to protect the generator against
electrical overload. The circuit breaker may be reset by pressing
the circuit breaker reset button.
AIR FILTER
The air filter helps to limit the amount of dirt and dust drawn
into the unit during operation.
CHOKE LEVER
The choke lever is used when starting the engine.
CIRCUIT PROTECTOR
Protects the battery charge circuit from short circuit.
CONTROL PANEL CORD
The 25-ft. control panel cord (Model No. RDEC25) has a
120/240 Volt, 20 Amp twist lock plug and a 12 Volt DC engine
control connector on each end. When using this cord with
the removable control panel, appropriate equipment can be
powered through the 2 x 120 Volt duplex GFCI outlets on the
removable control panel.
ENGINE SWITCH
The engine switch on the removable control panel is used either
alone or in combination with the recoil starter grip to start the
generator. To turn the engine off, place either engine switch in
the "OFF" position.
FUEL TANK
The fuel tank has a capacity of 8 gallons.
FUEL VALVE
Fuel flow from the fuel tank to the engine is turned on and off
using the fuel valve.
Maximum Output.........................................................8,750 W
Rated Frequency .............................................................60 Hz
DIMENSIONS
Length ............................................................................ 31 in.
Width ............................................................................... 30 in.
Height .............................................................................. 27 in.
Weight ......................................................................... 256 lbs.
GenSmart
MONITORING SYSTEM
™
The GenSmart monitoring system tracks usage and load and
alerts the operator when periodic engine maintenance is rec-
ommended.
NOTE: GenSmart
for the 120 Volt, 20 Amp GFCI outlets on the removable
control panel. It does not measure load on the 240 Volt,
30 Amp outlet.
GROUND TERMINAL
The ground terminal is used to assist in properly grounding
the generator to help protect against electrical shock. Consult
with a local electrician for grounding requirements in your area.
OFF SWITCH
To turn the engine off, press and hold the OFF switch until the
engine stops or turn the ignition switch to the OFF position.
OIL CAP/DIPSTICK
Remove the oil fill cap to check and add lubricant to the gen-
erator when necessary.
OIL DRAIN PLUG
When changing the engine lubricant, the oil drain plug is
removed to allow old engine lubricant to be drained.
RECEPTACLES
The following single phase, 60 Hz outlets on the control panel
can be used for operating appropriate equipment, electrical
lighting, tools, and motor loads: two 120 Volt duplex GFCI
20 Amp receptacles, and one 240 Volt AC, 30 Amp receptacle.
A 240 Volt AC, 20 Amp receptacle plugged into the side of the
removable control panel is available when the panel is detached.
RECOIL STARTER GRIP
The recoil starter is pulled to start the machine.
REMOVABLE CONTROL PANEL
The removable control panel can be wall-mounted for use with
the control panel cord for operation in a variety of locations.
10 — English
load indicators monitor the load only
™