OPERATION
reset button located underneath the GenSmart
5 seconds.
NOTE: Be careful to only press and hold the reset button
when you want the maintenance panel to be reset.
GENERATOR CONTROL PANEL
The stationary control panel has a twist-lock 240 Volt,
30 Amp outlet and circuit breakers.
OPERATING THE GENERATOR USING THE
WALL MOUNTED REMOVABLE CONTROL
PANEL
See Figure 17.
If the panel has been installed in a remote location:
Turn off the generator.
Connect the generator to the removable control panel
using the twist-lock plug and the 12 Volt DC engine control
connector on the provided control panel cord.
ONLY use a generator outdoors and far away from open
windows, doors, and vents. These openings can pull in
generator exhaust.
Connect up to two additional 25 ft. control panel cords
to the provided 25 ft. control panel cord. The total length
of all connected cords should not exceed 75 ft. or
three (3) RDEC25 control panel cords.
Connect the control panel cord to the generator.
Start the engine as described in Starting the Engine.
Add devices to the generator and monitor the load of
each added device using the GenSmart
MOVING THE GENERATOR
See Figures 18 - 19.
Turn the engine switch OFF ( O ). Disconnect any equip-
ment that is plugged into the generator.
Turn the fuel valve to the OFF position.
Allow 30 minutes of "cool down" time before storing the
machine.
For security, insert the pin to secure the handle before
transporting.
With your foot on the rear of the frame, tilt the machine
toward you until it balances on the wheels, then roll the
machine to the desired location.
LIFTING THE GENERATOR
See Figure 20.
Fold the handle to the down position. Never lift or carry
this product using the handle.
NOTE: This tool is heavy and requires several people to lift.
To avoid back injury, keep your knees bent and lift with your
legs, not your back, and get help when needed.
ELECTRIC START
display for
™
This generator model is provided with both electric start and
recoil start capabilities. Avoid prolonged cranking, as it can
damage the engine.
The battery provided is a nominal 12 volt sealed recharge-
able lead-acid battery and can be operated in any position
without leakage. It complies with non-spillable battery
regulations. Its convenient size offers a 30% reduction over
conventional batteries.
NOTE: New generators are shipped with the battery con-
nections disconnected. The positive and negative terminals
must be connected to the battery before the Electric Start
feature will work.
For initial battery connection, see Connecting Battery.
STARTING THE ENGINE
See Figures 21 - 22.
NOTICE:
On a level surface with the engine off, check the
lubricant level before each use of the generator.
NOTE: If location of generator is not level, the unit may not
start or may shut down during operation.
Unplug all loads from the generator.
Turn the fuel valve to the ON position.
Pull the choke out to the START position.
NOTE: If engine is warm or the temperature is above
display panel.
™
50˚F, push the choke in to the RUN position.
Place the engine switch in the ON position.
Slide down and hold the lock button while pushing the
engine switch to the START position.
NOTE: The battery may require charging before the gen-
erator can be started using only the engine switch. The
generator can be started by pulling the recoil starter grip.
Once the generator is started, the battery will charge as
the unit runs.
The generator can also be started by pulling the recoil
starter grip until the engine runs (a maximum of 6 times).
NOTE: Do not allow the grip to snap back after starting;
return it gently to its original place.
Allow the engine to run for 15-30 seconds, then push the
choke in to the RUN position.
15 — English