Commissioning; Configure; Setting The Tone; Set Colour Scheme - Mennekes AMTRON Compact 3,7 / 11 C2 Manuel D'utilisation Et D'installation

Masquer les pouces Voir aussi pour AMTRON Compact 3,7 / 11 C2:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 69

6. Commissioning

The tasks described in this section may only be
carried out by a qualified electrician.
6.1

Configure

In the top section of the housing, there are 4 configuration
switches and 2 rotary encoder switches, with which the
device can be configured.
1
2
S4
3
4
S3
S2
Fig. 9: Configure
„ 4 x configuration switches S4
The configuration switches S4.3 and S4.4 have no
function.
„ Blue rotary encoder switch S3
„ White rotary encoder switch S2
After the configuration is complete, a restart is
required.
6.1.1

Setting the tone

The tone output during startup can be set using the con-
figuration switch S4.1.
Î "Fig. 9: Configure"
Position
Configuration switch S4.1 = 1 (ON)
Configuration switch S4.1 = 0 (OFF)
(default setting)
f Set as desired.

6.1.2 Set Colour Scheme

The colour of the symbols "Standby" and "Charging" on
the LED information panel can be set using the configura-
tion switch S4.2.
Î "Fig. 9: Configure"
Configuration switch S4.2 = 1
(ON)
Configuration switch S4.2 = 0
(OFF) (default setting)
f Set as desired.

6.1.3 Set Operation Mode

The operating modes can be set using the rotary encoder
switch. To set the operating mode, a flat-tip screwdriver is
required.
Î "Fig. 9: Configure"
Î "3.4 Operating modes"
Blue rotary encoder switch S3: Maximum charging current
0, 1, 2 and 3
4
5
6
7
Tone
Tone off
Tone on
Position
Position(s)
Maximum charging current
16 A
13 A
10 A
8 A
6 A
The positions "8" and "9" are not populated. If
the blue rotary encoder switch S3 is set to "8" or
"9", a fault is displayed.
Colour Scheme
LED "Standby" = green
LED "Charging" = blue
LED "Standby" = blue
LED "Charging" = green
15
EN

Publicité

Table des Matières
loading

Table des Matières