Télécharger Imprimer la page

RIB AA30033 Mode D'emploi page 29

Publicité

Les langues disponibles
  • FR

Les langues disponibles

A - CONNEXIONS
T1
T2
JC
JB
JA
POWER
230 VAC
L1 - N
230Vac 50/60Hz POWER SUPPLY (TO BE DONE BY THE
J1
MANUFACTURER)
BLINKER (40 W MAX.)
U
CONNECTION TO JC CONTACTS OF THE CARD R2
J2
V-W
PED. BUTT.
PEDESTRIAN OPENING CONTACT (NO)
J3
A+ TEST
+24Vdc SAFETY STRIP SELF-TEST POWER SUPPLY
LSC
CLOSE LIMIT SWITCH THAT CUTS OFF THE MOTOR IN
CLOSING
COM
LIMIT SWITCH COMMON CONTACT
LSO
OPEN LIMIT SWITCH THAT CUTS OFF THE MOTOR IN
OPENING
STOP
STOP CONTACT (NC)
J4
OPEN
OPENING CONTACT (NC)
CLOSE
CLOSING CONTACT (NC)
K. BUTT.
SINGLE PULSE CONTACT (NO)
A+
ACCESSORIES POWER SUPPLY +24Vdc
A-
ACCESSORIES POWER SUPPLY -24Vdc
SIGNAL
GATE OPEN INDICATOR 24Vdc
COM
COMMON CONTACT (common line for all the command
and safety inputs)
EDGE NC
SAFETY STRIP CONTACT (NC)
AERIAL
RADIO ANTENNA
J5
COM
COMMON CONTACT (common line for all the command
and safety inputs)
PHOTO NC
PHOTOCELLS CONTACT (NC)
PROBE
IS NOT AVAILABLE
J6
ENCODER
IS NOT AVAILABLE
J7
RADIO
CONNECTOR FOR EXTERNAL RADIO RECEIVER 24Vdc
J8
J5
TR1
TR2
J4
J3
SW S1
J2
J1
MOTOR
CAPACITOR
S3
J7
J6
PROG.
S3
LOW SPEED
TR1
TR2
TORQUE
SW S1
SW S1
SW1
SW2
SW3
T1 - T2
T
JA
R-N
U-V-W
L1-N
JB
X-Y-Z
JC
29
29
29
29
J8
SW1
SW2
SW3
IT IS COMPULSORY TO
SET THE DIP 13 OF THE
CONTROL PANEL IN THE
ON POSITION.
PROGRAMMING BUTTON
IS NOT AVAILABLE
IS NOT AVAILABLE
DO NOT REMOVE THE JUMPER!
OTHERWISE THE OPERATOR WILL NOT WORK!
DIP-SWITCHES
CARD R2
POWER RELAYS FOR THE COMMAND OF THE MOTOR
SINGLE PHASE POWER SUPPLY
NEUTRAL
CONTACTS FOR THE EARTH CONECTION
MOTOR CONNECTION
SINGLE PHASE POWER SUPPLY FOR THE S1 CONTROL
PANEL TO BE DONE BY THE MANUFACTURER
CONNECTION TO THE POWER RELAYS, TO BE DONE
BY THE MANUFACTURER
NC: NORMALLY CLOSED CONTACT
NO: NORMALLY OPEN CONTACT
G
B

Publicité