No.
Name
5.1.1.0
Operating mode
5.1.2.0
Setting, MA/SL
5.1.3.0
Pump cycling
5.1.3.1
Manual pump
cycling
5.1.3.2
Internal/external
5.1.3.3
Internal: Time in-
terval
5.1.4.0
Pump enabled/
disabled
5.1.5.0
5.1.6.0
SBM
5.1.7.0
External off
5.2.0.0
BMS
5.2.1.0
LON / CAN / IF
module Wink/
Service
5.2.2.0
Local/remote
operation
5.2.3.0
Bus address
5.2.4.0
IF gateway val A
5.2.5.0
IF gateway val C
138
Installation and operating instructions • Wilo-CronoLine-IL-E, Wilo-CronoTwin-DL-E, Wilo-CronoBloc-BL-E • Ed.01/2024-02
Type Symbol
Values/explanations
Main/standby operation
±
Parallel operation
Manually switches from "Main pump" to
±
"Standby pump" (partner pump) mode
Carries out pump cycling independent of
±
the countdown
Internal pump cycling
±
External pump cycling
Can be set between 8 h and 36 h in 4 h
±
steps
Pump enabled
±
Pump disabled
Individual fault signal
±
Collective fault signal
Individual readiness signal
±
Individual run signal
Collective readiness signal
Collective run signal
Individual External off
±
Collective External off
Settings for Building Management System
(BMS) – building automation
The wink function permits the identification
±
of a device in the BMS network. A "wink" is
executed by confirmation.
BMS local operation
±
Remote BMS operation
Setting of bus address
±
Specific settings of the IF module, depends
±
on protocol type
±
Display conditions
Only displayed at the MA (main
pump)
Only displayed at the MA (main
pump)
Only displayed at the MA (main
pump)
Only displayed at the MA (main
pump)
Only displayed at the MA (main
pump)
Only displayed at the MA (main
pump)
Only displayed at the MA (main
pump), see "AUX" terminal
Displayed when internal pump cyc-
ling is activated
Only displayed at the MA (main
pump)
Only displayed at the MA (main
pump)
Only displayed at the MA (main
pump) and for SBM function
standby/run
Only displayed at the MA (main
pump)
Only displayed at the MA (main
pump)
Only displayed at the MA (main
pump)
Only displayed at the MA (main
pump)
Only displayed at the MA (main
pump)
Only displayed if BMS is active, incl.
all submenus
Only displayed when LON, CAN or IF
module is active
Temporary state, automatic reset to
remote operation after 5 min
Further information can be found in
the installation and operating in-
structions of the IF modules