Zodiac iAquaLink CONTROL Z550iQ Notice D'installation Et D'utilisation page 59

Masquer les pouces Voir aussi pour iAquaLink CONTROL Z550iQ:

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 1
2
Compressor Over Current
BLDC1 motor speed is
18
abnormal
4.2.1 Clearing error codes
If a fault occurs 4 times in less than 60 minutes, the error code remains displayed even if the condition involving it has
disappeared. In this case, press
In the case of an isolated fault, the error code remains displayed as long as the fault condition is active and is automatically
cleared if the fault condition disappears.
4.3 I Lighting of LEDs on the printed circuit board
LED5
No errors
Appliance
switched on
Error 04
Error 05
Error 06
Error 07
Error 08
Error 09
Error 10
Error 11
Error 12
Error 14
Error 15
Error 16
Error 17
Error 18
Error 19
Error 20
: LED on
The compressor Load is too high
Compressor cable disconnected
or is not connected properly
Compressor is damaged
Check fan motor
to clear the fault.
LED4
: Flashing LED
Power OFF and then power ON the unit
Check wiring of the compressor's phases
- Measure the winding values
- Check compressor insulation
Replace fan motor if necessary
LED3
LED2
Empty: LED off
EN
LED1
25