Télécharger Imprimer la page

Zodiac iAquaLink CONTROL Z550iQ Notice D'installation Et D'utilisation page 56

Masquer les pouces Voir aussi pour iAquaLink CONTROL Z550iQ:

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 1
• Before you contact the retailer, carry out these few simple checks using the following tables if
a problem occurs.
• If the problem is not resolved, contact your retailer.
: Actions to be performed by a qualified technician only
4.1 I Appliance behaviour
• On start-up, the appliance remains "paused" for 30 seconds before it starts operating.
• When the setpoint temperature is reached, the appliance stops heating: the water temperature
The appliance
does not start
• When the water flow rate is zero or is not enough, the appliance stops: check that the water is
heating straight
• The appliance stops when the outdoor temperature falls below -12 °C.
away
• The appliance may have detected an operating fault (see § "4.2 I Error code display").
• If you have checked these points and the problem persists: contact your retailer.
• Often called condensates, this water is the moisture contained in the air which condenses on
The appliance
is discharging
water
• To check that the water is not coming from a leak in the pool circuit on the appliance, shut it down
• The appliance will soon switch to its defrost cycle to melt the ice.
The evaporator is
• If the appliance cannot manage to defrost its evaporator, it will stop itself; this means that the
iced over
• This may occur when the appliance is in a defrost cycle and the water is converted to gas.
The appliance is
• If the appliance is not in its defrost cycle, this is not normal. Switch off and disconnect the
"smoking"
• When the setpoint temperature is reached, the appliance stops heating: the water temperature
The appliance is
• When the water flow rate is zero or is not enough, the appliance stops: check that the water is
not working
• The appliance stops when the outdoor temperature falls below -12 °C.
• The appliance may have detected an operating fault (see § "4.2 I Error code display").
• The operating mode is not powerful enough (appliance in "ECOSILENCE" or "SMART" mode).
• The appliance may have detected an operating fault (see § "4.2 I Error code display").
The appliance
• Check that the automatic filling valve is not stuck in open position; this will keep supplying cold
is working
but the water
• There is too much heat loss as the air is cool. Install a heat insulated cover on the pool.
temperature
• The appliance is unable to capture enough calories as its evaporator is clogged with dirt. Clean it
does not
increase
• Check that the external environment is not hindering the heat pump (see § "❶ Installation").
The fan is
running but
• If the outdoor temperature is low, the appliance will perform defrost cycles.
the compressor
• The appliance is unable to capture enough calories as its evaporator is clogged with dirt. Clean it
stops from time
to time with no
error message
The appliance
trips the circuit
breaker
22
❹ Troubleshooting
is higher than or equal to the setpoint temperature.
circulating correctly in the appliance and that the hydraulic connections are correct.
contact with certain cold mechanisms in the appliance, especially on the evaporator. The damper
the air, the more condensates your appliance will produce (your appliance may drain several
litres of water per day). This water is retrieved by the base of the appliance and drained through
the holes.
and run the filter pump to circulate water in the appliance. If the water continues to flow through
the condensate drainage lines, there is a water leak in the appliance; contact your retailer.
outdoor temperature is too low (below -12°C).
appliance immediately and contact your retailer.
If there is no display, check the supply voltage and the F1 fuse.
is higher than or equal to the setpoint temperature.
circulating correctly in the appliance.
Switch to "BOOST" mode and set the filtration to 24/24 manual while the temperature rises.
water into the pool and will prevent the temperature from rising.
to restore its performances (see § "3.2 I Maintenance").
Check that the appliance is the right size for this pool and its environment.
to restore its performances (see § "3.2 I Maintenance").
Check that the circuit breaker is correctly dimensioned and that the cable section used is
correct (see § "5.2 I Technical data").
The supply voltage is too low; contact your electricity supplier.

Publicité

loading