1.2 I Hydraulic connections
• The device will be connected with a Ø50 PVC pipe, using the half union connectors supplied (see § "5.1 I
Description"), to the pool's filtration circuit, after the filter and before the water treatment.
• Respect the direction of hydraulic connection.
• A by-pass must be installed to make it easier to work on the appliance.
Connection to a standard filtration circuit
• To evacuate the condensates, fit a Ø18 pipe on the grooved elbow to be mounted under the appliance base.
Condensate drainage orientation (seen from below the appliance)
Tip: condensate drainage
• Caution, several litres of water can be drained from your appliance each day. We strongly recommend
connecting the drain to a suitable water drainage system.
• We also recommend tilting the appliance slightly backwards (using the adjustable studs) for better
condensate drainage.
: water inlet valve
: by-pass valve
: water outlet valve
: water inlet adjustment valve
(optional)
: water outlet adjustment valve
(optional)
: water treatment
* minimum distance