Télécharger Imprimer la page

Keysight EL30000 Serie Guide D'utilisation page 97

Publicité

Les langues disponibles

Les langues disponibles

Parameter
Available Key
Settings
Trigger Source
Key, IO, or Rmt
Trigger Delay
0 to 0.255 s
Step 2 – Run the input sequence
In this example, the load operation is in CV mode.
– Set V
, pulse width, trigger delay and repeat count accordingly: Use the navigation keys to select the field; use the
1
numeric entry keys to enter the value. The value is set when you press [Enter] .
– Set Trigger Source to Key. Press Trig Src Key .
– Press the color-coded [On] key to enable the selected input.
– Press Run to start the sequence operation. To abort the operation, press Stop .
– Press Back to exit and return to the previous menu.
Keysight EL30000 Series User's Guide
Sets the trigger source for the system.
Default is Key.
Action required:
Press Trig Src to toggle between Key, IO, and Rmt.
Key (List Run/Stop Key)
IO (DIO Trigger In)
Rmt (Remote Command)
Sets the trigger delay in seconds.
Default is 0 s.
Description
Selects the Run Stopped softkey as a trigger
source.
Selects any configured digital IO (with Trigger
Input function) as a trigger source
Selects a remote interface command as a trigger
source.
97

Publicité

loading

Ce manuel est également adapté pour:

El33133aEl34143aEl34243a