Télécharger Imprimer la page

Keysight EL30000 Serie Guide D'utilisation page 88

Publicité

Les langues disponibles

Les langues disponibles

Using the Sequencer Function (EL34143A and EL34243A only)
LIST mode
Continuous mode
Pulse mode
Toggle mode
There are four types of sequencer mode: LIST, Continuous, Pulse, and Toggle.
Press Sequencer to select the sequencer type.
Press Back to return to Sequencer main menu.
LIST mode
LIST mode lets you generate complex sequences of input changes with rapid, precise timing, which may be
synchronized with internal or external signals. This is useful when running test sequences with a minimum amount
of programming overhead.
The Sequencer LIST allows single or multiple inputs to run in sequence. You can set the followings for each of the
input in sequence.
1. Set the step that will generate the trigger out signal at the beginning/end of the step.
2. Set the last input value after the sequence list completes.
3. Set how the list responds to triggers.
4. Set the transient mode for voltage and current.
5. Set the trigger source for the transient system.
6. Set the trigger delay in seconds.
7. Set the list repeat count.
8. Set the list to repeat continuously.
You can configure up to 100 steps in the Sequencer LIST window.
Step 1– Add/remove steps to/from the LIST
Press Sequencer to access the Sequencer LIST window.
88