Parameter
Available Key Settings
Trigger Source
Key, IO, or Rmt
Trigger Delay
0 to 0.255 s
Repeat Count
1 to 9999
Continuous
-
Step 2 – Run the input sequence
In this example, the load operation is in CV mode.
– Set V
, period, frequency, duty cycle, trigger delay and repeat count accordingly: Use the navigation keys to
1
select the field; use the numeric entry keys to enter the value. The value is set when you press [Enter] .
– Set Trigger Source to Key. Press Trig Src Key .
– Press the color-coded [On] key to enable the selected input.
– Press Run to start the sequence operation. To abort the operation, press Stop .
– Press Back to exit and return to the previous menu.
94
Sets the trigger source for the system.
Default is Key.
Action required:
Press Trig Src to toggle between Key, IO, and Rmt.
Key (List Run/Stop Key)
IO (DIO Trigger In)
Rmt (Remote Command)
Sets the trigger delay in seconds.
Default is 0 s.
Sets the list repeat count. This sets the number of times that a list is executed before it
completes.
Default is 1.
Enables check box to repeat the list continuously.
Description
Selects the Run Stopped softkey as a trigger
source.
Selects any configured digital IO (with Trigger
Input function) as a trigger source
Selects a remote interface command as a trigger
source.