Front Panel Menu Reference
This is an overview of the front-panel menus. Press the softkeys to access the front panel menus.
Menu heading
Mode>
       CC
       CV
       CR
       CP
Load Settings >
       Mode >
       Sense
       Protection >
       Range >
       Short
Input Settings>
       On/Off Coupling >
       Output Inhibit >
       Operation Mode >
Sequencer >
       Sequencer >
Utilities >
       Store / Recall >
       I/O Config >
       Test/Setup >
       Error >
       Manage Files >
Lock | Unlock
60
Description
Constant current (CC) mode.
In this mode, the load will sink a current in accordance with the programmed value regardless of the
input voltage.
Constant voltage (CV) mode.
In this mode, the load will attempt to sink enough current to maintain the input voltage at its pro-
grammed value.
Constant resistance (CR) mode.
In this mode, the load will sink current proportional to the input voltage in accordance with the pro-
grammed resistance.
Constant power (CP) mode.
In this mode, the load will regulate the power being drawn from the DUT according to the pro-
grammed constant-power value.
Configures the operating mode to CC, CV, CR, or CP.
Configures the load input sense to 2-wire or 4-wire.
Configures the protection setting for the load input.
Configures the measurement range for load input.
Enable or disable the input short.
Enables or disables the input coupling or synchronization between multiple input channels.
Configures the inhibit input mode and Digital IO Pin 3.
Configures the input capability when two independent inputs are being used. (EL34243A only)
Configures the sequencer type: LIST, Continuous, Pulse, and Toggle.
Saves and recalls instrument states.
Displays and configures the I/O parameters for remote operations over the USB, LAN, GPIB, or
digital IO interface.
Accesses the self-test, calibration, and help function as well as configures the user preferences, and
sets date and time.
Displays the instrument's error queue. Errors will be cleared after viewing or instrument reset.
Creates, copies, deletes, and renames files and folders on the USB drive attached to the front panel.
Also allows you to capture the current screen to either a bitmap (*.bmp) or portable network graph-
ics (*.png) file.
Locks and unlocks the display.
Keysight EL30000 Series User's Guide